2010
DOI: 10.1016/j.fluid.2010.03.004
|View full text |Cite
|
Sign up to set email alerts
|

New analytic apparatus for experimental determination of vapor–liquid equilibria and saturation densities

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…Solubility measurements of solids in carbon dioxide were performed in an apparatus based on the static-analytic technique. This is mainly constituted by a high-pressure view-cell, a six-port two-way valve (Valco, C-2006E), a high-performance liquid chromatograph (Agilent, 1100 series), a syringe pump (Isco, 100DM), and an air bath (France Etuves, model XL074SP). The schematic diagram of the apparatus is presented in Figure .…”
Section: Methodsmentioning
confidence: 99%
“…Solubility measurements of solids in carbon dioxide were performed in an apparatus based on the static-analytic technique. This is mainly constituted by a high-pressure view-cell, a six-port two-way valve (Valco, C-2006E), a high-performance liquid chromatograph (Agilent, 1100 series), a syringe pump (Isco, 100DM), and an air bath (France Etuves, model XL074SP). The schematic diagram of the apparatus is presented in Figure .…”
Section: Methodsmentioning
confidence: 99%
“…The experimental procedure for the simultaneous determination of the vapor-liquid equilibrium and saturated densities was recently published by Galicia-Luna and Elizalde-Solis [24]. It basically consists on the following parts:…”
Section: Methodsmentioning
confidence: 99%
“…The law of propagation of errors detailed by Taylor and Kuyatt [26] was applied to Eq. (1) [24]. Associated uncertainties which contribute to Eq.…”
Section: Calibration Of the Measurement Instrumentsmentioning
confidence: 99%
“…Initially, the apparatus used was based on the static-analytic method and has been designed to perform fast determinations of vapor–liquid equilibria and critical pressures up to 60 MPa and 523 K . However, in order to determine other thermophysical properties within the phase equilibrium, a second experimental apparatus was developed to simultaneously determine at high pressures liquid–vapor equilibrium or vapor–liquid–liquid equilibrium and saturation densities. , Actually, both apparatuses are part of the experimental facilities of the Thermodynamics Laboratory.…”
Section: Introductionmentioning
confidence: 99%