New approach for quantification of left ventricular function from low-dose gated bloodpool SPECT: Validation and comparison with conventional methods in patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 21 publications
0
7
0
Order By: Relevance
“…8 At present, conventional planar ERNA has recently gained less favor due to the growing concern of radiation exposure (740 MBq; 5.18 mSV) to patients. 13,14 As Giubbini et al 11 explain, planar imaging is limited by the overlap of different cardiac structures affecting the calculation of LVEF, especially in the presence of mitral regurgitation, the valvular function cannot be explored, and the volumes of heart chambers are only roughly determined. Though, when compared to planar image acquisition, SPECT ERNA acquired with high-sensitivity CZT cameras can be done with lower radiation dose, faster image acquisition time, and improved reproducibility.…”
Section: 65mentioning
confidence: 99%
See 1 more Smart Citation
“…8 At present, conventional planar ERNA has recently gained less favor due to the growing concern of radiation exposure (740 MBq; 5.18 mSV) to patients. 13,14 As Giubbini et al 11 explain, planar imaging is limited by the overlap of different cardiac structures affecting the calculation of LVEF, especially in the presence of mitral regurgitation, the valvular function cannot be explored, and the volumes of heart chambers are only roughly determined. Though, when compared to planar image acquisition, SPECT ERNA acquired with high-sensitivity CZT cameras can be done with lower radiation dose, faster image acquisition time, and improved reproducibility.…”
Section: 65mentioning
confidence: 99%
“…Currently, ERNA is used to: (A) quantify left ventricular and right stroke volumes and ejection fractions in patients with moderate to severe tricuspid regurgitation, 19 (B) obtain measures of dyssynchrony to predict outcomes in heart failure patients, [20][21][22][23] (C) assess left ventricular function and mechanical dyssynchrony in patients with right ventricular outflow tract pacing and right ventricular apical pacing, 24 (D) study the accuracy of automated LVEF measurements in the presence of large perfusion defects in a myocardial infarction, in which the estimation of endocardial borders might be expected to be difficult because of reduced or absent counts, requiring some degree of extrapolation with a geometric model, 25,26 (E) evaluate left and right ventricular volumes and function in patients with left ventricular assist devices, 2 (F) analyze the left and right ventricular function after surgical repair of Tetralogy of Fallot, 27 (G) validate ( Table 2) the ventricular function assessment by other imaging techniques, 13,25,[28][29][30][31][32][33][34] and (H) analyze left and right ventricular function before lung transplant ( Figure 2). Furthermore, in oncologic patients treated with chemotherapy, ERNA is a good imaging technique to detect systolic dysfunction through left and right ventricular ejection fraction analysis.…”
Section: Journal Of Nuclear Cardiologyòmentioning
confidence: 99%
“…Three-dimensional gated blood pool SPECT is similar to the previous method, but it has the potential to differentiate cardiac chambers better than planar radionuclide ventriculography. Automatic measurement of the LVEF by [ 99m Tc]gated blood-pool SPECT (GBPS) provides accurate segmental wall motion analysis and estimates the cavity volume in a single examination [54,55]. Nevertheless, there is a good agreement in the rough calculation of LVEF between MUGA and GBPS methods [56].…”
Section: Single-photon Emission Computed Tomography (Spect)mentioning
confidence: 99%
“…13,17,18 A similar finding was also recently reported for cardiac bloodpool imaging (Figure 1). 12,19 As a result of the new collimation systems, the count sensitivity of these CZT cameras is three to sevenfold higher than that of a conventional dual-head gamma camera. 16 This ratio in Figure 1.…”
mentioning
confidence: 99%
“…In the present issue of the Journal of Nuclear Cardiology, 19 a novel approach using gated bloodpool SPECT and a reduced radioactive dose is presented. The underlying rationale is that an integration of all LV short-axis slices in a 2D display, mimicking a left anterior oblique view, will allow reaching high levels of LV counts per pixel as well as high signal-to-noise ratios.…”
mentioning
confidence: 99%