1998
DOI: 10.1109/60.707603
|View full text |Cite
|
Sign up to set email alerts
|

New approach to determine the critical capacitance for self-excited induction generators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0
1

Year Published

2003
2003
2017
2017

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 44 publications
(14 citation statements)
references
References 9 publications
0
13
0
1
Order By: Relevance
“…When the R-L load is connected to self the complex form of the differential equ linkages chosen as state variables in the a frame is given [8] where subscript 's' denote is for rotor:-ω…”
Section: Induction Machine Modementioning
confidence: 99%
See 1 more Smart Citation
“…When the R-L load is connected to self the complex form of the differential equ linkages chosen as state variables in the a frame is given [8] where subscript 's' denote is for rotor:-ω…”
Section: Induction Machine Modementioning
confidence: 99%
“…The same author also determined the optimal size of capacitance for maximum output power of the generator in [7]. [8] have attempted the determination of the critical value of capacitance using complex impedance matrix method of SEIG. Recently [9] has determined the boundary values of excitation capacitance and minimum load impedance for wind driven SEIG.…”
Section: Introductionmentioning
confidence: 98%
“…Nombreuses sont les études qui appréhendent ce problème d'auto-amorçage de manière numérique [33], [34], [35], pour déterminer ce qui est qualifié de capacité critique d'autoamorçage. La transformation utilisée est celle de Park (transformation à deux axes).…”
Section: Ii) Modelisation Numerique Du Generateurunclassified
“…Despite all of this, commercialization of an asynchronous machine as an isolated asynchronous generator (IAG) is still a bottleneck because of its unsatisfactory voltage and frequency regulation and power quality problems, even when driven under constant power prime mover and feeding frequently varying loads [4]. As the asynchronous machine is isolated, the reactive power for its operation may be supplied by a VAR generating unit connected across its terminals, which is generally realised using the capacitor banks [5,6]. The capacitor banks are selected such that when driven at rated speed, they should produce the rated voltage at no-load operating under magnetic saturation.…”
Section: Introductionmentioning
confidence: 99%