2004
DOI: 10.1007/s00402-003-0606-9
|View full text |Cite
|
Sign up to set email alerts
|

New concepts in the treatment of ankle joint fractures

Abstract: The XS nail which is introduced here fulfils the requirements made of an implant as regards maximum protection of soft tissue, secure fracture fixation and early exercise tolerance, including ankle fractures. No implant dislocation, no deep infection and no re-osteosynthesis were observed. Its advantages over conventional techniques lie precisely in the treatment of complex fractures and for patients with poor bone, vascular and soft-tissue situations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0
1

Year Published

2004
2004
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(21 citation statements)
references
References 13 publications
0
20
0
1
Order By: Relevance
“…Trial, [6][7][8] and 7 techniques in 9 case series alone. [9][10][11][12][13][14][15][16][17][18] Some techniques were reported in multiple publications.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Trial, [6][7][8] and 7 techniques in 9 case series alone. [9][10][11][12][13][14][15][16][17][18] Some techniques were reported in multiple publications.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…In the period from 05/2000 to 01/2002, 194 ankle fractures were treated with the IP-XS-Nail ® [2]. The patients were observed prospectively and a follow-up examination was carried out after on average 15 months.…”
Section: Resultsmentioning
confidence: 99%
“…An additional axial screw was used for further compression at the medial malleolus because of the transverse fracture pattern. c) Radiographs after implant removal (1 year after the operation).Im Zeitraum 05/2000-01/2002 wurden 194 Sprunggelenkfrakturen mit dem IP-XS-Nagel ® versorgt[2]. Die Patienten wurden prospektiv beobachtet und durchschnittlich 15 Monate postoperativ nachuntersucht.…”
unclassified
“…13 Several studies reviewing intramedullary fixation of fibular fractures have reported significantly lower rates of wound breakdown and hardware irritation than seen traditionally with standard AO techniques. 2,5,8,10,12,14,15 The majority of complications seen in early descriptions of the procedure were minimized as the technique evolved. 2 For example, malunion in early, unlocked designs was as high as 20% compared to 5% in a more contemporary locked design.…”
Section: Discussionmentioning
confidence: 99%