2011
DOI: 10.1016/j.ijepes.2010.12.006
|View full text |Cite
|
Sign up to set email alerts
|

New control approach for capacitor supported DSTATCOM in three-phase four wire distribution system under non-ideal supply voltage conditions based on synchronous reference frame theory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
40
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 98 publications
(40 citation statements)
references
References 15 publications
0
40
0
Order By: Relevance
“…The reference signals thus obtained are compared with the actual compensating filter currents in a hysteresis comparator, where the actual current is forced to follow the reference and provides instantaneous compensation by the APF [14] on account of its easy implementation and quick prevail over fast current transitions. This consequently provides switching signals to trigger the IGBTs inside the inverter.…”
Section: Instantaneous Active and Reactive Current (I D -I Q ) Methodsmentioning
confidence: 99%
“…The reference signals thus obtained are compared with the actual compensating filter currents in a hysteresis comparator, where the actual current is forced to follow the reference and provides instantaneous compensation by the APF [14] on account of its easy implementation and quick prevail over fast current transitions. This consequently provides switching signals to trigger the IGBTs inside the inverter.…”
Section: Instantaneous Active and Reactive Current (I D -I Q ) Methodsmentioning
confidence: 99%
“…The design of the PLL is based on concepts of instantaneous power theory in the dq reference frame. This device also synchronizes, by providing the phase h, the coordinate transformations from abc to dq components in the voltage and current measurement system [17]. These signals are then filtered by using second-order lowpass filters in order to obtain the fundamental components employed in the control system.…”
Section: Frequency Control Modementioning
confidence: 99%
“…The active power P d absorbed by the d branch is P d = P d1 + P dH , where P d1 is the fundamental active power and P dH is the harmonic active power (or nonfundamental active power) [10] that the d branch absorbs. (2) shows that their sum for the r branches of the network is zero,…”
Section: Powers Of Network With Nonsinusoidal Periodic Voltages and mentioning
confidence: 99%
“…A line of research on electrical power which began in the nineteenth century [1][2][3] and continues today [4][5][6][7] has been mainly directed at better quantifying the behavior of electrical power systems and creating concepts to optimize their design [8][9][10]. This investigation has produced many definitions of electric powers [11].…”
Section: Introductionmentioning
confidence: 99%