1987
DOI: 10.1007/bf00200337
|View full text |Cite
|
Sign up to set email alerts
|

New detection method for uropepsinogen (PGA) using isoelectric focusing and immunoblotting techniques

Abstract: Uropepsinogen (PGA) was isolated and purified from human urine using a column chromatography series. The purified PGA was injected into a rabbit and a PGA-specific antibody was obtained. PGA isozymogen in human urine could be detected reproducibly by immunoblotting using this antibody after isoelectric focusing electrophoresis (IEF) on polyacrylamide gels. This technique may prove to be useful in the genetic study of PGA polymorphism.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1988
1988
1997
1997

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…After IEF-PAGE, the isozymes was transferred onto a Durapore strip (Millipore) essentially according to the method described in our previous papers [4][5][6][7][8]. In the case of SDS-PAGE, transfer was carried out by electroblotting using a KS-8453 apparatus (Marysol, Tokyo, Japan).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…After IEF-PAGE, the isozymes was transferred onto a Durapore strip (Millipore) essentially according to the method described in our previous papers [4][5][6][7][8]. In the case of SDS-PAGE, transfer was carried out by electroblotting using a KS-8453 apparatus (Marysol, Tokyo, Japan).…”
Section: Methodsmentioning
confidence: 99%
“…The combination of IEF-PAGE and immunoblotting with a specific antibody has been used as a valuable technique for investigating possible heterogeneity and new genetic polymorphisms of pepsinogen [4,5], deoxyribonuclease [6,7] and a urinary glycoprotein, GP 43 [8]. Accordingly, immunological detection of the secretory RNase in body fluids seems most suitable for genetic or forensic distinction between the two RNases coexisting in body fluids [1].…”
Section: Introductionmentioning
confidence: 99%
“…These plasma samples were stored at -80°C until the DNase I phenotyping was performed. Urine samples were concentrated, dialyzed and finally lyophilized, as described previously [7,8]. A 0.1 Vo w/v solution of the lyophilized material, corresponding to tenfold concentrated urine, was used for DNase I phenotyping.…”
Section: Biological Samplesmentioning
confidence: 99%