New echocardiographic diameter for Amplatzer sizing in adult patients with secundum atrial septal defect: Preliminary results

Abstract: Anatomical atrial septal defect (ASD) diameter measured by transesophageal echocardiography (TEE) underestimates the Amplatzer septal occluder (ASO) size for ASD closure. The aim of this study is to investigate whether a new echocardiographic diameter (procedural ASD diameter) may enable precise measurements of ASO device size. Fifty adult patients with secundum ASD were evaluated by TEE for percutaneous closure. The procedural ASD diameter was measured using the steadier rim borders where thickness was 2.5 mm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2004
2004
2013
2013

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(17 citation statements)
references
References 55 publications
0
17
0
Order By: Relevance
“…Recently, Carcagni and Presbitero [16] suggested using the thickest part of the rim around the ASD (2.5 mm thick), providing much better correlation with the BSD and very little scatter. Their results need to be confirmed.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, Carcagni and Presbitero [16] suggested using the thickest part of the rim around the ASD (2.5 mm thick), providing much better correlation with the BSD and very little scatter. Their results need to be confirmed.…”
Section: Discussionmentioning
confidence: 99%
“…The Amplatzer septal occluder has a central waist for closure of the defect and two disks for fixation. Accurate assessment of the location and size of the ASD and surrounding rims is essential for determining whether implantation of an Amplatzer septal occluder or surgical repair is appropriate (4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17). TTE is a useful screening tool for the detection of ASD.…”
Section: Discussionmentioning
confidence: 99%
“…Nevertheless, some anatomic conditions have been described as being troublesome for Amplatzer septal occluder closure. These conditions include small atrial capacity, which can limit full expansion of the disks of the Amplatzer occluder; floppy septum, which can cause prolapse of the occluder; thin septum, which can easily be torn after deployment of the occluder, and large ASD, which can be underestimated with resultant dislodgment of the occluder (15)(16)(17).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…During balloon occlusion, color Doppler evaluation of the atrial septum to rule out additional atrial defects should be carried out. However, I do not routinely perform balloon sizing, but rely on the TEE sizing; I utilize the thick margins of the defect to measure the size of the ASD, leaving out the flail margins, a method similar to that suggested by Carcagnì and Presbitero (2004).…”
Section: Methods Of Device Implantationmentioning
confidence: 99%