2012
DOI: 10.1016/j.radmeas.2012.02.006
|View full text |Cite
|
Sign up to set email alerts
|

New luminescence measurement facilities in retrospective dosimetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
35
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 49 publications
(37 citation statements)
references
References 19 publications
2
35
0
Order By: Relevance
“…The spatial homogeneity of the 90 Sr/ 90 Y beta source (ID 155, produced prior to 2000) used for the single grain measurements presented here was determined using radiochromic film (GAFCHROMIC EBT2) and the coefficient of variation was found to be ~5%, which is unlikely to affect our dose distributions significantly. Using the approach developed by Lapp et al (2012) to correct for spatial beta source heterogeneity, no significant changes in dose or scatter in our dose distributions could be detected, which is consistent with the observations of Sim et al (2014) for the same source. Thus, the laboratory beta dose rate employed in further single grain calculations is based on the average over the whole disc.…”
Section: Quartz Single Grain Oslsupporting
confidence: 87%
“…The spatial homogeneity of the 90 Sr/ 90 Y beta source (ID 155, produced prior to 2000) used for the single grain measurements presented here was determined using radiochromic film (GAFCHROMIC EBT2) and the coefficient of variation was found to be ~5%, which is unlikely to affect our dose distributions significantly. Using the approach developed by Lapp et al (2012) to correct for spatial beta source heterogeneity, no significant changes in dose or scatter in our dose distributions could be detected, which is consistent with the observations of Sim et al (2014) for the same source. Thus, the laboratory beta dose rate employed in further single grain calculations is based on the average over the whole disc.…”
Section: Quartz Single Grain Oslsupporting
confidence: 87%
“…Mapping the beta source following the approach of Lapp et al (2012) 435 showed that the effective dose rate varied spatially by up to 5% and 13% for the 436 sources ID155 and ID195, respectively. Lapp et al (2012) have developed software 437 that makes it possible to correct for this dose rate inhomogeneity automatically using 438 this dose-rate map. This source inhomogeneity contributes to the intrinsic over-439 18 dispersion discussed in the previous section; the size of this contribution can be 440 determined by analysing a bleached and gamma dosed sample with and without 441 correction for inhomogeneity.…”
Section: Effect Of Beta Source Inhomogeneity 424mentioning
confidence: 99%
“…The β-source in the single grain reader has been checked for inhomogeneity of its irradiation field, as this can be of importance for the single grain measurements. Applying the method proposed by Lapp et al (2012) using a β-radiation sensitive self-developing film it was concluded that non-uniformity of the β-source is minor and hence no correction on the single grains measurements was applied.…”
Section: Equipment and Equivalent Dose Determinationmentioning
confidence: 99%