2005
DOI: 10.1117/12.613017
|View full text |Cite
|
Sign up to set email alerts
|

New method of structure light measurement system calibration based on adaptive and effective evaluation of 3D-phase distribution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
32
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
5
3
1

Relationship

4
5

Authors

Journals

citations
Cited by 34 publications
(32 citation statements)
references
References 0 publications
0
32
0
Order By: Relevance
“…The measurement uncertainty of 3D shape determination of the method used is less than 0.001 with respect to the measurement volume size. 19 Measurement of the 3D surface lies beyond the scope of the CIE theory, where the L ‫ء‬ a ‫ء‬ b ‫ء‬ color space is used to calculate color differences, because the theory requires the sample to have a well defined measurement geometry and lighting condition. Therefore, it is very difficult to propose an objective method to evaluate the results from a multispectral color measurement system.…”
Section: Verification Of Measurement Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The measurement uncertainty of 3D shape determination of the method used is less than 0.001 with respect to the measurement volume size. 19 Measurement of the 3D surface lies beyond the scope of the CIE theory, where the L ‫ء‬ a ‫ء‬ b ‫ء‬ color space is used to calculate color differences, because the theory requires the sample to have a well defined measurement geometry and lighting condition. Therefore, it is very difficult to propose an objective method to evaluate the results from a multispectral color measurement system.…”
Section: Verification Of Measurement Resultsmentioning
confidence: 99%
“…It relies on acquiring a set of images of a calibration reference plane in different positions within measurement volume and calculating the phase distribution within this volume. 7,19 Second, during the color calibration, three sequences of measurement procedure are performed: one with the reference plane with markers to compensate for deviations in spectral filter positioning, one with a white reference plate put in the measurement volume for light source spectrum compensation, and one with a uniformly colored background to eliminate uneven illumination in the scene. Ideally, a calibration process could rely on capturing an image of white reference plate which covers the whole field of view of the detector for each spectral channel.…”
Section: Multispectral Color Measurement Systemmentioning
confidence: 99%
“…It is further processed in order to obtain a set of (x, y, z) co-ordinates (cloud of points) representing the sampled surface of the measured subject. For the calculation of (x, y, z) co-ordinates a calibration matrix is used 11 . 3DMADMAC system can be customized depending on the requirements of the end-user connected with measurement volume size, amount of measurement points, measurement uncertainty and time of a single measurement.…”
Section: Measurement Methods and Systemmentioning
confidence: 99%
“…A target-based calibration procedure depends on the camera calibration performed using a previously developed method [16]. A planar target with circular markers is used as a reference (see Figure 4.).…”
Section: Camera Calibrationmentioning