2016
DOI: 10.3311/ppci.8545
|View full text |Cite
|
Sign up to set email alerts
|

New Precast Wall Connection Subjected to Rotational Loading

Abstract: Abstract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(14 citation statements)
references
References 19 publications
0
14
0
Order By: Relevance
“…In the current decade, few types of wall to wall horizontal connections have been introduced to the construction industry such loop connection, wire loop and U-shape steel channel. The structural behaviors of loop connection have been investigated by [2,11,13,17] in terms of anchorage length, bonding and tensile. The section is to shed the light on types of precast wall to wall horizontal connections and their structural behaviours.…”
Section: Types Of Wall To Wall Horizontal Connectionmentioning
confidence: 99%
See 2 more Smart Citations
“…In the current decade, few types of wall to wall horizontal connections have been introduced to the construction industry such loop connection, wire loop and U-shape steel channel. The structural behaviors of loop connection have been investigated by [2,11,13,17] in terms of anchorage length, bonding and tensile. The section is to shed the light on types of precast wall to wall horizontal connections and their structural behaviours.…”
Section: Types Of Wall To Wall Horizontal Connectionmentioning
confidence: 99%
“…In loop connection, the overlapping area of the U-bar loops, the spacing of the loops, the strength of the joint material and, finally, the transverse reinforcement in the overlapping area influence the tensile capacity [13]. Therefore, the preferred mode of failure for the loop connection is yielding of reinforcement rather that crushing of mortar.…”
Section: A Loop Connectionmentioning
confidence: 99%
See 1 more Smart Citation
“…Wei proposed a vertical connection joint with a flange section steel for shear walls. From an economic point of view, the flange plate should not be arranged over the full length of the wall . A new connection method to improve the rotational loading capacity of shear wall is proposed, and specialists established a numerical model of assembled walls by considering all of the details of the different components .…”
Section: Introductionmentioning
confidence: 99%
“…From an economic point of view, the flange plate should not be arranged over the full length of the wall. [27] A new connection method to improve the rotational loading capacity of shear wall is proposed, and specialists established a numerical model of assembled walls by considering all of the details of the different components. [28] A ductile connection of U-shaped steel plate has been applied in the United States.…”
mentioning
confidence: 99%