“…Equations (5)- (9) indicate that there is coupling introduced by the transformer between the α axis and β axis. Equations (5) and (6) can be transformed into the two-phase rotating coordinate by the Park transform:…”
Section: Complex State Variable Structure Of Invertermentioning
confidence: 99%
See 1 more Smart Citation
“…Equations (5)- (9) indicate that there is coupling introduced by the transformer between the α axis and β axis. Equations (5) and (6) can be transformed into the two-phase rotating coordinate by the Park transform:…”
Section: Complex State Variable Structure Of Invertermentioning
confidence: 99%
“…There are many kinds of topologies to meet the above requirements, such as the split capacitor inverter (SCI) [1,2], four-leg inverter [3][4][5][6][7][8][9], and neutral point forming transformer (NFT) inverter [10,11]. The split capacitors of SCI not only act as support capacitors, but also provide the route of the unbalanced current and ripple current, which means that split capacitors have a larger volume and weight, and the ripple current in support capacitors and filter capacitors is larger than in other structures, which makes the capacitors be vulnerable to the ripple current.…”
Section: Introductionmentioning
confidence: 99%
“…Based on estimation, it is assumed that the switching power losses are sinusoidal, while Equations (17) and (18) define the sine function peak of E on and E o f f , respectively, at the peak evaluation of the collector current. An approximation of the summation in Equation (19) can be given by the integration as in Equation (20):…”
Section: Switching Lossesmentioning
confidence: 99%
“…In order to accommodate to unbalanced load, the common modulation strategy for the three-phase four-leg inverter is threedimensional space vector pulse width modulation (3D-SVPWM) with high utilisation of DC voltage and good flexibility, which is presented comprehensively by the authors of [20][21][22][23][24]. The simplified 3D-SVPWM algorithm is proposed by Li et al [20], which alleviates the computation burden of the processor.…”
Section: Introductionmentioning
confidence: 99%