2019
DOI: 10.1016/j.jmbbm.2019.04.002
|View full text |Cite
|
Sign up to set email alerts
|

Newer vs. older CAD/CAM burs: Influence of bur experience on the fatigue behavior of adhesively cemented simplified lithium-disilicate glass-ceramic restorations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 19 publications
(5 citation statements)
references
References 47 publications
0
5
0
Order By: Relevance
“…In this study, the shear bond test was performed for monotonic and fatigue tests, in which the monotonic values were used to obtain the fatigue profile and load steps for the survival curve of each thickness group. This methodology was widely applied in studies that evaluated failures in restorative materials, 12,14,28,29 however, never with the present setup to test shear bond durability. In this study, the cement thickness was standardized by applying a specific amount of weight using an adapted apparatus device for each specimen (►Fig.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this study, the shear bond test was performed for monotonic and fatigue tests, in which the monotonic values were used to obtain the fatigue profile and load steps for the survival curve of each thickness group. This methodology was widely applied in studies that evaluated failures in restorative materials, 12,14,28,29 however, never with the present setup to test shear bond durability. In this study, the cement thickness was standardized by applying a specific amount of weight using an adapted apparatus device for each specimen (►Fig.…”
Section: Discussionmentioning
confidence: 99%
“…The Author(s). materials,12,14,28,29 however, never with the present setup to test shear bond durability.…”
mentioning
confidence: 91%
“…Finally, it should be emphasized that this in vitro study has inherent limitations to mimic the clinical situation, as the bond strength is affected by diverse factors including the technique [34], acid concentration and etching time [35], and laser irradiation energy [15] and by heat treatment protocols [33].…”
Section: Discussionmentioning
confidence: 99%
“…This may have an impact on the misfit discrepancies among the study groups. Furthermore, it is suggested that the cutting efficiency, sequence, and duration of use of burs can influence the properties of ceramics including its surface [37][38][39] . The burs were continuously changed on the manufacturers' recommendations, which differed between systems.…”
Section: Discussionmentioning
confidence: 99%