2014
DOI: 10.1016/j.ijhydene.2014.07.053
|View full text |Cite
|
Sign up to set email alerts
|

Ni-YSZ cermets for solid oxide fuel cell anodes via two-step firing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 41 publications
0
3
0
1
Order By: Relevance
“…The reduced Ni/ScSZ samples has higher total conductivity than NiO/ScSZ. Although, there are only few or no reports for the total conductivity of Ni/ Zr 0.84 Sc 0.16 O 1.92 with 1:1 wt % composition, the conductivity is lower if compared to the reported Ni/YSZ cermet, which is about 300-1000 S/cm [17,18]. This may be due to the limitation of the EIS measurement employed in this study compared to the four-point probe direct current (DC) technique.…”
Section: Resultsmentioning
confidence: 83%
“…The reduced Ni/ScSZ samples has higher total conductivity than NiO/ScSZ. Although, there are only few or no reports for the total conductivity of Ni/ Zr 0.84 Sc 0.16 O 1.92 with 1:1 wt % composition, the conductivity is lower if compared to the reported Ni/YSZ cermet, which is about 300-1000 S/cm [17,18]. This may be due to the limitation of the EIS measurement employed in this study compared to the four-point probe direct current (DC) technique.…”
Section: Resultsmentioning
confidence: 83%
“…In the actual work one intended to minimize undue microstructural changes, such as loss of porosity yielded by the dispersed droplets of organic phase. Controlled microstructural changes are also expected for zirconia-based 2phase systems [24], probably requiring higher temperatures to overcome constraints imposed by a secondary refractory phase. Thus, the levels of isothermal plateau for the actual TZP-Al 2 O 3 cellular ceramics were 200ºC higher than demonstrated for single-phase TZP [23].…”
Section: Methodsmentioning
confidence: 99%
“…Pengukuran impedansi dalam penelitian ini dilakukan pada rentang frekuensi 20 -5 Hz dan kisaran suhu 300 -600 o C. Penggunaan pasta perak sebagai elektroda pengukuran impedansi tidak memungkinkan untuk melakukan pengukuran pada suhu di atas 600 o C, karena ada kemungkinan pasta perak akan meleleh dan terdifusi ke dalam material yang sedang diukur. Pengukuran suhu tinggi, > 600 o C membutuhkan pasta platina, sehingga dimungkinkan konduktivitas total dari Ni-YSZ yang terukur lebih tinggi, seperti halnya pengukuran pada Ni-YSZ 37 yang disintesis dari zirconia komersial, yaitu antara 170 -240 S.cm -1 (Davarpanah et al, 2014).…”
Section: Conductivity (S/cm)unclassified