Abstract:An automated and high-throughput (36 h–1) method
for extremely sensitive determination of the two main tellurium species
in the environment, namely, tellurite (TeIV) and tellurate
(TeVI), was developed. Flow injection hydride generation
was interfaced for the first time with inductively coupled plasma
triple quadrupole mass spectrometry (ICP–MS/MS) detection to
assure interference-free tellurium analysis. ICP–MS/MS conditions
were studied in detail. Using a mixture of He + O2 gases
in the reaction cell, the ba… Show more
“…The method was successfully validated against the NRCC CRMs SLRS-3 and 4 (river water). In the HG-ICP-MS determination of Te, elimination of 128 Xe and 130 Xe interferences on the most abundant isotopes 128 Te and 130 Te meant 79 that an LOD of 0.07 ng L −1 could be achieved, thereby making the determination of Te in lake, river, bottled and seawaters possible. Results for total Te in six CRMs agreed well with certificate values.…”
This review covers advances in the analysis of air, water, plants, soils and geological materials by a range of atomic spectrometric techniques including atomic emission, absorption, fluorescence and mass spectrometry.
“…The method was successfully validated against the NRCC CRMs SLRS-3 and 4 (river water). In the HG-ICP-MS determination of Te, elimination of 128 Xe and 130 Xe interferences on the most abundant isotopes 128 Te and 130 Te meant 79 that an LOD of 0.07 ng L −1 could be achieved, thereby making the determination of Te in lake, river, bottled and seawaters possible. Results for total Te in six CRMs agreed well with certificate values.…”
This review covers advances in the analysis of air, water, plants, soils and geological materials by a range of atomic spectrometric techniques including atomic emission, absorption, fluorescence and mass spectrometry.
“…Garcia-Figueroa et al explored the capabilities of ICP-MS/MS to reduce the influence of spectral interferences on the most natural abundant Te isotopes. 122 For this purpose, FI-HG was interfaced to ICP-MS/MS. Most of the paper is devoted to the optimisation of the experimental conditions affecting HG-ICP-MS/MS.…”
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.