2016
DOI: 10.1016/j.compositesb.2016.04.073
|View full text |Cite
|
Sign up to set email alerts
|

Non destructive monitoring of cavitation erosion of cordierite based coatings

Abstract: Coating materials are widely used in refractory lining to prevent different deleterious effects such are reactions on the mold-metal contact surface, abrasion from liquid metal or alloy, gasses, slags, and other materials in contact with the coating. In this paper, behavior of cordierite based coating exposed to the cavitation erosion was investigated. Cordierite samples sintered at 1200 and 1400 °C were used for the tests. Mass loss, level of surface degradation obtained using image analysis and thermal imagi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 30 publications
0
6
0
1
Order By: Relevance
“…Cavitation erosion testing was performed using ultrasonic vibration method (with stationary specimen) according to standard procedure [14,15]. The usual characteristics for the frequency and peak-to-peak displacement amplitude of the horn were used, as well as characteristics of liquid are described in details in previous papers [8,9,16,[24][25].…”
Section: Methods 221 Cavitation Erosion Testingmentioning
confidence: 99%
See 3 more Smart Citations
“…Cavitation erosion testing was performed using ultrasonic vibration method (with stationary specimen) according to standard procedure [14,15]. The usual characteristics for the frequency and peak-to-peak displacement amplitude of the horn were used, as well as characteristics of liquid are described in details in previous papers [8,9,16,[24][25].…”
Section: Methods 221 Cavitation Erosion Testingmentioning
confidence: 99%
“…Monitoring of the surface erosion caused by the cavitation and hence the surface damage level were performed by image analysis as an addition to the standard laboratory procedure of the mass loss measuring [8,9,[24][25]. Image Pro Plus (IPP) program [27] was used in analysis of the sample surfaces.…”
Section: Image Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…Za ispitivanje uzoraka talka +15% zeolita sa ležšta "Igroš" sinterovanih na 1200°C primenjena je ultrazvučna vibraciona metoda (sa stacionarnim uzorkom) prema standardu ASTM G32 [21]. Izbor karakterističnih parametara za ovu metodu kao što su frekvenca vibracije talasovoda, temperatura tečnosti, udaljenost uzorka od čeone površine sonde, karakteristike tečnosti izabrani su u skladu sa standardom i ranijim radovima [19][20][21][22][23].…”
Section: Određivanje Otpornosti Uzorka Na Dejstvo Kavitacijeunclassified