2021
DOI: 10.1007/s13404-020-00287-w
|View full text |Cite
|
Sign up to set email alerts
|

Non-enzymatic colorimetric sensor for cardiac Troponin I (cTnI) based on self-assembly of gold nanorods on heparin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 24 publications
0
4
0
Order By: Relevance
“…177 Also, heparin-gold nanorods (H-AuNRs) self-assembly nonenzymatic colorimetric detection for cTnI was reported. 178 Similar to this finding, Bhalla et al have developed aptamer-AuNPs and peptide-AuNPs dual nanoprobes for selective aggregationinduced colorimetric detection of cTnI. 179 Wu et al developed a creatine kinase (CK-MM) biomarker detection using aggregation of cysteamine (Cys) functionalized AuNPs in the presence of ATP.…”
Section: Optical Signaling Readout-based Nanobiosensorsmentioning
confidence: 80%
See 1 more Smart Citation
“…177 Also, heparin-gold nanorods (H-AuNRs) self-assembly nonenzymatic colorimetric detection for cTnI was reported. 178 Similar to this finding, Bhalla et al have developed aptamer-AuNPs and peptide-AuNPs dual nanoprobes for selective aggregationinduced colorimetric detection of cTnI. 179 Wu et al developed a creatine kinase (CK-MM) biomarker detection using aggregation of cysteamine (Cys) functionalized AuNPs in the presence of ATP.…”
Section: Optical Signaling Readout-based Nanobiosensorsmentioning
confidence: 80%
“…This system performs with a 0.5–20 ng/mL linear range and the limit of detection at 0.3 ng/mL . Also, heparin-gold nanorods (H-AuNRs) self-assembly nonenzymatic colorimetric detection for cTnI was reported . Similar to this finding, Bhalla et al have developed aptamer-AuNPs and peptide-AuNPs dual nanoprobes for selective aggregation-induced colorimetric detection of cTnI .…”
Section: Optical Signaling Readout-based Nanobiosensorsmentioning
confidence: 99%
“…More importantly, LOD reached a value as low as 17 pg mL −1 . Compared with other reports related to cTnI determination (Table 1), 13,[37][38][39][40][41][42][43][44][45] the prepared lanthanide-doped NPs-based LFA has the merits of relatively low LOD and wide linear range. As for colorimetry, it is hard to distinguish the intermediate color with the naked eye.…”
Section: Analytical Performance Of Lfa Platformmentioning
confidence: 87%
“…Furthermore, AuNRs have been demonstrated to provide a visual detection of cTnI in the case of non-enzymatic colorimetric sensors. Recently, Raj et al conducted a study that implies the aggregation of AuNRs with heparin [ 26 ]. Concretely, CTAB-stabilized AuNRs are exposed to heparin, which, due to electrostatic interaction, induces an aggregation of the AuNRs and, implicitly, a reduction in the LSPR wavelength.…”
Section: Surface Plasmon Resonance-based Biosensorsmentioning
confidence: 99%