2004
DOI: 10.1016/s0140-6736(04)15436-6
|View full text |Cite
|
Sign up to set email alerts
|

Non-invasive assessment of hepatic iron stores by MRI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

14
562
0
30

Year Published

2004
2004
2022
2022

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 607 publications
(606 citation statements)
references
References 26 publications
14
562
0
30
Order By: Relevance
“…The measurement of LIC by highly T2*-weighted MRI was demonstrated to correlate well with the iron content assessed by invasive liver biopsy [24,27,31]. Iron determination by MRI is a reproducible, sensitive, and noninvasive method that can reduce the need for liver biopsies to assess liver iron content especially in thrombocytopenic patients.…”
Section: Discussionmentioning
confidence: 86%
See 1 more Smart Citation
“…The measurement of LIC by highly T2*-weighted MRI was demonstrated to correlate well with the iron content assessed by invasive liver biopsy [24,27,31]. Iron determination by MRI is a reproducible, sensitive, and noninvasive method that can reduce the need for liver biopsies to assess liver iron content especially in thrombocytopenic patients.…”
Section: Discussionmentioning
confidence: 86%
“…Bone marrow iron stores were assessed semiquantitatively on Prussian-blue-stained marrow smears according to the following scale: grade 0= absent; 1=decreased; 2=normal; 3=increased; 4=markedly increased; 5=massively increased. LIC was determined quantitatively by T2*-weighted MRI as described previously [24][25][26]. An LIC >35-µmol/g liver tissue was considered as iron overload.…”
Section: Methodsmentioning
confidence: 99%
“…Numerous MRI methods have been proposed for liver iron evaluation and quantification [10]. Hepatic iron can be assessed by measuring signal intensity ratios (SIRs) of the liver and of a reference tissue with good correlation [11]. Direct measurement of the relaxation time (relaxometry) can also quantify liver iron by either measuring T2 relaxation times from spin echo sequences or T2* relaxation times (or relaxation rates R2*) from gradient echo sequences [4,12].…”
mentioning
confidence: 99%
“…The method was applied for the first time by Hernandez et al [14] to gradient-echo sequences. A further development of the method was published by Gandon et al [19]. Gandon's method is based on the postulated linear relationship between the LIC and signal intensity ratio (SIR) depending on the protocol.…”
Section: Signal-intensity Ratiomentioning
confidence: 99%