Abstract: Blood pressure is an extremely important blood hemodynamic parameter. The pulse wave contains abundant blood-pressure information, and the convenience and non-invasivity of its measurement make it ideal for non-invasive continuous monitoring of blood pressure. Based on combined photoplethysmography and electrocardiogram signals, this study aimed to extract the waveform information, introduce individual characteristics, and construct systolic and diastolic blood-pressure (SBP and DBP) estimation models using th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 42 publications
0
8
0
Order By: Relevance
“…This earlier study has very high correlation coefficients, 0.999 and 0.998, respectively, for the SBP and DBP. Another study by Wu et al [ 7 ] also used ECG and PPG with the hybrid ANN method, and produced 3.404 mmHg and 3.289 mmHg, respectively, for SBP and DBP. Meanwhile, a study by Eom et al [ 8 ] conducted an investigation of multiple input signals, ECG, PPG, and BCG, combined with CNN, Bi-GRU, and attention methods.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This earlier study has very high correlation coefficients, 0.999 and 0.998, respectively, for the SBP and DBP. Another study by Wu et al [ 7 ] also used ECG and PPG with the hybrid ANN method, and produced 3.404 mmHg and 3.289 mmHg, respectively, for SBP and DBP. Meanwhile, a study by Eom et al [ 8 ] conducted an investigation of multiple input signals, ECG, PPG, and BCG, combined with CNN, Bi-GRU, and attention methods.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, electrocardiography (ECG) and PPG, with ANN and long short-term memory (LSTM) methods were applied for the evaluations [ 6 ]. Backpropagation with a genetic algorithm (GA) was also used for hemodynamics evaluation [ 7 ]. Meanwhile, another study utilized ballistocardiography (BCG) and ECG alongside the PPG with convolutional neural networks (CNN) and a gated recurrent units (GRU)-based technique [ 8 ].…”
Section: Introductionmentioning
confidence: 99%
“…Current commercial wearables and WIoT technologies can monitor and collect only a small portion of the physiological data and biomarkers (see Fig. 4 ) [1] , [18] [27] . The sensor modalities implemented to measure physiological symptoms at the onset of COVID-19 include (but are not limited to) the temperature, HR using an electrocardiogram (ECG); pulse plethysmography (PPG); HR variability using ECG and PPG; blood pressure using PPG; respiratory rate using ECG, PPG, and an accelerometer; oxygen saturation (SpO2) using PPG; sleep using an accelerometer; and cough using mechanical or piezoelectric sensing.…”
Section: Role Of Iot In Managing Covid-19mentioning
confidence: 99%
“…New optical wearables and RPM technologies have the potential to address many clinical scenarios related to the COVID-19 pandemic. Table 2 contains a brief summary of opportunities for remote and wearable optical technology development, both for COVID-19 and for the many Optical scattering FD-DOS, TD-DOS, SFDI, 40 OCT, 41 ESS Glucose Spectroscopy [42][43][44] Blood pressure PPG 45,46 Images of the eye, skin Ophthalmology, 47 OCT, 41 smartphone-based dermoscopy 48 Images of the cervix Colposcopy 49…”
Section: Areas Of Opportunity For the Biomedical Optics Community To mentioning