Non-Invasive Fluidic Glucose Detection Based on Dual Microwave Complementary Split Ring Resonators With a Switching Circuit for Environmental Effect Elimination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
34
1
3

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 81 publications
(39 citation statements)
references
References 37 publications
1
34
1
3
Order By: Relevance
“…In line with previous work by the authors [ 29 , 31 , 33 ], a linear relationship with a sensitivity of 0.00026 dB/(mg/dl) was observed for the RF mm-wave data, Figure 1 b, between the transmission S 21 and the amount of glucose concentration in the samples. This sensitivity is comparable to the sensitivity of other transmission-based RF systems at lower frequencies, which can range between 0.00008–0.00140 dB/(mg/dl) [ 29 , 34 , 35 , 36 , 37 ]. This approximately linear relationship is also evident for the NIR transmittance data, with a sensitivity of 0.00019%/(mg/dl) ( Figure 1 a).…”
Section: Resultssupporting
confidence: 56%
“…In line with previous work by the authors [ 29 , 31 , 33 ], a linear relationship with a sensitivity of 0.00026 dB/(mg/dl) was observed for the RF mm-wave data, Figure 1 b, between the transmission S 21 and the amount of glucose concentration in the samples. This sensitivity is comparable to the sensitivity of other transmission-based RF systems at lower frequencies, which can range between 0.00008–0.00140 dB/(mg/dl) [ 29 , 34 , 35 , 36 , 37 ]. This approximately linear relationship is also evident for the NIR transmittance data, with a sensitivity of 0.00019%/(mg/dl) ( Figure 1 a).…”
Section: Resultssupporting
confidence: 56%
“…First, microwave sensors are suitable for noninvasive, nondestructive and noncontact measurements [8]- [10]. Moreover, their size can be reduced by increasing the operating frequency, and they can be easily incorporated into commercial mobile communication systems [11], [12].…”
Section: Introductionmentioning
confidence: 99%
“…Our research group developed an improved glucose sensor with environmental effect elimination [ 104 ]. The effects of both temperature and relative humidity on the performance of the sensor were analyzed mathematically.…”
Section: Radio-frequency/microwave-based Glucose Sensorsmentioning
confidence: 99%
“…( b ) Variation in the transmission coefficient of the sensor as a function of the glucose concentration after environmental effect elimination. (Reprinted with permission from [ 104 ]; published by IEEE, 2020.)…”
Section: Figurementioning
confidence: 99%