2015
DOI: 10.1049/iet-pel.2014.0824
|View full text |Cite
|
Sign up to set email alerts
|

Non‐linear adaptive hysteresis band pulse‐width modulation control for hybrid active power filters to reduce switching loss

Abstract: Pulse-width modulations (PWMs) are widely investigated in active power filter (APF) applications. However, there are seldom PWMs proposed in hybrid APF (HAPF) applications because of their non-linear current characteristic. This study proposes a non-linear adaptive hysteresis band PWM controller for HAPFs to reduce the switching loss and keep the total harmonic distortion (THD) at an acceptable level. In contrast to previous studies, as the coupling LC impendence of an HAPF can yield a non-linear compensating … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(22 citation statements)
references
References 22 publications
0
22
0
Order By: Relevance
“…Some researchers are interested in virtual hybrid APFs, that is an APF between an AC and DC micro-grid [107]. To research finding novel control strategies to improve the performance of hybrid filters has always been popular for researchers [108][109][110][111][112][113].…”
Section: Hybrid Active Power Filtersmentioning
confidence: 99%
“…Some researchers are interested in virtual hybrid APFs, that is an APF between an AC and DC micro-grid [107]. To research finding novel control strategies to improve the performance of hybrid filters has always been popular for researchers [108][109][110][111][112][113].…”
Section: Hybrid Active Power Filtersmentioning
confidence: 99%
“…The d-q fundamental voltages, (5) and (6) can be represented in terms of the modulator signals and the DC voltage V dc , where V dinv = V dc m dinv /2 and V qinv = V dc m qinv /2. Thus, by solving (5) and (6) for i d and i q currents and then substituting these values in (15), the following expression for the i dc and the DC power produced, P dc , are:…”
Section: Inner and Outer Controllermentioning
confidence: 99%
“…(3) It makes the relay protection device act by mistake, which interrupts the power supply and makes the extent loss to production. (4) It interferes with measuring instruments and communication systems [6][7][8]. erefore, it is urgent to control the power harmonic pollution to improve the power quality.…”
Section: Introductionmentioning
confidence: 99%