2012
DOI: 10.1097/mbp.0b013e32834f710b
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive measurement of beat-to-beat arterial blood pressure by the Korotkoff sound delay time

Abstract: The beat-to-beat blood pressure estimated by KDT provides an accurate estimate of MAP in the preliminary experiments and represents a potential acceptable alternative to invasive blood pressure monitoring during laboratory studies.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…The experimental system is similar to that in [9] It includes four units: i) an analog circuit unit to condition the cuff pressure, oscillometric pulse, Korotkoff sounds and invasive blood pressure (IBP); ii) a microprocessor (C8051F060) to receive the analog signals and send them to the computer; iii) a set of automatic inflating and deflating appliance controlled by the microprocessor to realize the linear deflation of the cuff; iv) a personal computer with self-programmed data acquiring and analyzing software [9].…”
Section: Components Of the Systemmentioning
confidence: 99%
See 3 more Smart Citations
“…The experimental system is similar to that in [9] It includes four units: i) an analog circuit unit to condition the cuff pressure, oscillometric pulse, Korotkoff sounds and invasive blood pressure (IBP); ii) a microprocessor (C8051F060) to receive the analog signals and send them to the computer; iii) a set of automatic inflating and deflating appliance controlled by the microprocessor to realize the linear deflation of the cuff; iv) a personal computer with self-programmed data acquiring and analyzing software [9].…”
Section: Components Of the Systemmentioning
confidence: 99%
“…2, the Korotkoff sound delay time for the four cardiac cycles at different cuff pressure demonstrate that T1 at is the longest while T4 is the shortest. In a series of the KDTs of the whole measurement in cuff deflation, the KDT corresponding to the first Korotkoff sound is the longest, while the KDTs corresponding to the subsequent Korotkoff sound become shorter and shorter respectively, and the shortest one appears at the last Korotkoff sound [9].…”
Section: Korotkoff Sound Delay Timementioning
confidence: 99%
See 2 more Smart Citations