2005
DOI: 10.1088/0967-3334/26/6/021
|View full text |Cite
|
Sign up to set email alerts
|

Noninvasive measurement of blood pressure variability: accuracy of the Finometer monitor and comparison with the Finapres device

Abstract: To assess the accuracy of spectral indices of arterial pressure variability and baroreflex sensitivity obtained from beat-by-beat noninvasive blood pressure recordings by the Finometer device, we compared these measures with those obtained from intra-arterial recordings. The performance of the Finometer was also compared to the traditional Finapres device. In 19 cardiac disease patients, including myocardial infarction, heart failure and cardiac transplant, we estimated the power of systolic and diastolic pres… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
27
0
4

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(34 citation statements)
references
References 25 publications
3
27
0
4
Order By: Relevance
“…15) Blood pressure variability was also assessed using variances of beat-to-beat systolic blood pressure obtained from the finger sphygmomanometer. 16) The power spectra of the high-frequency component (0.15-0.40 Hz) of heart rate variability and low-frequency component (0.04-0.15 Hz) of blood pressure variability were analyzed by the maximum entropy method using MemCalc (TARAWA, GMS, Tokyo). 15,16) The high-frequency and low-frequency components reflect cardiac parasympathetic and sympathetic activities, respectively.…”
Section: )mentioning
confidence: 99%
See 2 more Smart Citations
“…15) Blood pressure variability was also assessed using variances of beat-to-beat systolic blood pressure obtained from the finger sphygmomanometer. 16) The power spectra of the high-frequency component (0.15-0.40 Hz) of heart rate variability and low-frequency component (0.04-0.15 Hz) of blood pressure variability were analyzed by the maximum entropy method using MemCalc (TARAWA, GMS, Tokyo). 15,16) The high-frequency and low-frequency components reflect cardiac parasympathetic and sympathetic activities, respectively.…”
Section: )mentioning
confidence: 99%
“…16) The power spectra of the high-frequency component (0.15-0.40 Hz) of heart rate variability and low-frequency component (0.04-0.15 Hz) of blood pressure variability were analyzed by the maximum entropy method using MemCalc (TARAWA, GMS, Tokyo). 15,16) The high-frequency and low-frequency components reflect cardiac parasympathetic and sympathetic activities, respectively. [15][16][17][18] Transcutaneous oxygen pressure in foot (Foot-tcPO 2 ) was measured as a parameter of peripheral blood circulation using a transcutaneous oxygen pressure device (PO-850, Sumitomo Electric Hightechs, Tokyo).…”
Section: )mentioning
confidence: 99%
See 1 more Smart Citation
“…Рівень барорефлекторної чутливості, що оці-нювався крос-спектральним методом по когерент-ності між коливаннями кардіоінтервалу та систоліч-ного артеріального тиску у діапазоні 0,067-0,133 Гц, на 116 молодих чоловіках показав високий рі-вень відтворюваності при триразових повторних вимірах з інтервалом у один тиждень [67]. Maestri R. et al [83] при повторних вимірюваннях парамет-рів спонтанної барорефлекторної чутливості на 44 здорових чоловіках і 57 -із інфарктом міокарду знайшли їх добру повторюваність.…”
Section: характеристика та теоретичні основи методів аналізу варіабелunclassified
“…У результаті тиск у манжеті починає повторювати зміни тиску у артерії. За допомогою приладів Finapres можна оцінювати хвильову структуру ко-ливань артеріального тиску та чутливість бароре-флексу в основному з такою ж точністю, як і при катетеризації артеріальних судин [83,117]. У US National Library of Medicine на даний момент (квітень 2017 року) існує 800 посилань на дослі-дження, виконані з використанням такої технології.…”
Section: огляди літературиunclassified