2017 IEEE Power and Energy Conference at Illinois (PECI) 2017
DOI: 10.1109/peci.2017.7935731
|View full text |Cite
|
Sign up to set email alerts
|

Nonlinear control of standalone inverter with unbalanced, nonlinear load

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…where and are the series equivalent resistance and inductance of the output filter and the grid impedance respectively, is the capacitance of the DC link, ( ) is the grid voltage, ( ) is the inverter output current, ( ) and ( ) are the PV voltage and current, ( ) is the duty ratio control signal, and 0 represents the unknown disturbances, which could appear physically in the circuit such as imperfect switch timing [41].…”
Section: Simulation Results Of the Single-phase Pv Systemmentioning
confidence: 99%
See 3 more Smart Citations
“…where and are the series equivalent resistance and inductance of the output filter and the grid impedance respectively, is the capacitance of the DC link, ( ) is the grid voltage, ( ) is the inverter output current, ( ) and ( ) are the PV voltage and current, ( ) is the duty ratio control signal, and 0 represents the unknown disturbances, which could appear physically in the circuit such as imperfect switch timing [41].…”
Section: Simulation Results Of the Single-phase Pv Systemmentioning
confidence: 99%
“…Then, the method proposed in [46] is adopted in this dissertation to obtain the model of the single-phase system in dq frame. Additionally, based on the preceded work, the nonlinear controller is combined with adaptive control to adaptively estimate the unknown disturbances that physically appear in the circuit such as imperfect switching timing [41]. …”
Section: List Of Tablesmentioning
confidence: 99%
See 2 more Smart Citations
“…In this chapter a backstepping controller developed in 0-frame is proposed for the control of a 3-phase 4-wire diode clamped inverter with output filter under different loads including balanced, unbalanced, linear and nonlinear loads [64]. In addition, an observer is developed for load-current estimation, enhancing the behavior of the proposed controller especially for the cases that there is a need to remove the costly output current sensor.…”
Section: Backstepping Controller For 3-phase Inverter With Seamless Tmentioning
confidence: 99%