2015
DOI: 10.1063/1.4921474
|View full text |Cite
|
Sign up to set email alerts
|

Nonlinear photoacoustic spectroscopy of hemoglobin

Abstract: As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(20 citation statements)
references
References 14 publications
0
20
0
Order By: Relevance
“…Although nonlinear RSA materials are anticipated to be the most promising dye category for generation of an enhanced nonlinear PA response it must be kept in mind that their application is very much limited to scenarios where the application of high laser fluences is feasible. While a number of studies addressing nonlinear PAI have emerged very few have involved in vivo studies , none of which have relied solely on a molecular‐based contrast agent. As such, all of the in vivo imaging applications of MPACs discussed in this review have been conducted under low laser fluence conditions where the dye either behaves as a LA or SA material.…”
Section: Classes Of Photoacoustic Contrast Agentsmentioning
confidence: 99%
See 1 more Smart Citation
“…Although nonlinear RSA materials are anticipated to be the most promising dye category for generation of an enhanced nonlinear PA response it must be kept in mind that their application is very much limited to scenarios where the application of high laser fluences is feasible. While a number of studies addressing nonlinear PAI have emerged very few have involved in vivo studies , none of which have relied solely on a molecular‐based contrast agent. As such, all of the in vivo imaging applications of MPACs discussed in this review have been conducted under low laser fluence conditions where the dye either behaves as a LA or SA material.…”
Section: Classes Of Photoacoustic Contrast Agentsmentioning
confidence: 99%
“…PAI can also be considered noninvasive. For example, hemoglobin can be used as an endogenous contrast agent to obtain histological imaging and has even been investigated ex vivo for nonlinear PAI . However, the addition of exogenous PA contrast agents allows for microscopic imaging with far greater selectivity and contrast at a cellular and molecular level.…”
Section: Introductionmentioning
confidence: 99%
“…The lock-in detection method is also designed for measuring nonlinear PA, motivated by the potential for 3D enhanced resolution. The source of PA nonlinearities [31][32][33][34] varies between different samples and excitations and can be classified in the following categories; 1saturation and damage effects, 2-thermal nonlinearities and 3-phase transformations in the sample or its surroundings. All mechanisms are characterized by a nonlinear relation of the PA amplitude to the laser fluence.…”
Section: Nonlinear Pamentioning
confidence: 99%
“…The most commonly photo absorbers for PA imaging and sensing can be classified into two categories based on their primary absorbing wavelengths: (1) in the visible regions (400–700 nm), the primary absorbers for PA include hemoglobin [ 40 , 60 ], cytochrome [ 61 ], melanin [ 62 ], DNA/RNA [ 49 , 63 ], myoglobin [ 64 ]; (2) in the near-infrared region (700–1400 nm), lipid [ 65 , 66 ], glucose [ 45 , 67 ] are also strong absorbers for PA emission. Figure 1 summarizes the absorption spectrum of common endogenous contrasts [ 68 ].…”
Section: Principlesmentioning
confidence: 99%