2023
DOI: 10.1016/j.teac.2023.e00216
|View full text |Cite
|
Sign up to set email alerts
|

Nontarget screening strategies for PFAS prioritization and identification by high resolution mass spectrometry: A review

Boris Bugsel,
Jonathan Zweigle,
Christian Zwiener
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 79 publications
0
5
0
Order By: Relevance
“…In this context, the application of non-targeted approaches is fundamental to discover new molecules, as only a few dozen of the several thousand existing per-and polyfluoroalkyl chemicals can be monitored by traditional targeted analysis. Accordingly, by applying liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS/MS), recent studies of biotic and environmental samples have revealed several PFASs not previously described [23][24][25][26][27][28][29][30][31][32][33][34][35].…”
Section: Introductionmentioning
confidence: 99%
“…In this context, the application of non-targeted approaches is fundamental to discover new molecules, as only a few dozen of the several thousand existing per-and polyfluoroalkyl chemicals can be monitored by traditional targeted analysis. Accordingly, by applying liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS/MS), recent studies of biotic and environmental samples have revealed several PFASs not previously described [23][24][25][26][27][28][29][30][31][32][33][34][35].…”
Section: Introductionmentioning
confidence: 99%
“…4,5 Thus, current analytical trends emphasize complementary approaches based on organofluorine sum parameters and non-target screening (NTS) for a higher PFAS coverage. [6][7][8] Organofluorine sum parameters are used to determine the gap between PFAS targets and total organically bound fluorine and thereby indicate the quantity of unidentified extractable organic fluorine (EOF). 9 EOF sample preparation is combined with fluorine-sensitive and -specific detection systems like high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS).…”
Section: Introductionmentioning
confidence: 99%
“…15 For PFAS, several intrinsic properties can be used for feature prioritization in NTS. 6 The chemical mass defect (MD) is often used for prioritization of potentially unknown PFAS by removing features outside a defined MD range https://doi.org/10.26434/chemrxiv-2024-gj9fw ORCID: https://orcid.org/0000-0002-7194-1567 Content not peer-reviewed by ChemRxiv. License: CC BY-NC 4.0 4 due to the typically high number of F atoms resulting in negative to slightly positive MDs.…”
Section: Introductionmentioning
confidence: 99%
“…Per- and polyfluoroalkyl substances (PFAS) are ubiquitous contaminants posing adverse effects to humans and the environment. , The analysis of PFAS in environmental samples is very challenging because of their diverse physical/chemical properties and the high number of individual PFAS compounds . Target analysis is not feasible for a comprehensive characterization as only a few PFAS can be quantified, thereby often drastically underestimating the total PFAS burden. , Thus, current analytical trends emphasize complementary approaches based on organofluorine sum parameters and nontarget screening (NTS) for a higher PFAS coverage. …”
Section: Introductionmentioning
confidence: 99%
“…Eventually, the acquired information is usually compared with chemical databases (suspect screening) and molecular structures of the analytes are identified without the need for analytical standards . For PFAS, several intrinsic properties can be used for feature prioritization in NTS . The chemical mass defect (MD = m / z accurate – m / z nominal ) is often used for prioritization of potentially unknown PFAS by removing features outside a defined MD range due to the typically high number of F atoms resulting in negative to slightly positive MDs. , However, many other compounds fall in the same MD range as PFAS, hence, further improved prioritization is required to reduce false positives.…”
Section: Introductionmentioning
confidence: 99%