2020
DOI: 10.1016/j.bios.2020.112525
|View full text |Cite
|
Sign up to set email alerts
|

Normal-incidence type solution immersed silicon (SIS) biosensor for ultra-sensitive, label-free detection of cardiac troponin I

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 47 publications
0
5
0
Order By: Relevance
“…Specifically, the SIS sensor operates by directing in through a buffer solution, a bio-layer, and a substrate layer (SiO2). In this con the buffer solution serves as the incident medium, whose role is to provide temperature and humidity environment; errors due to refractive index chan tremely eliminated at the Brewster angle, resulting in a sensitivity more tha higher than conventional ellipsometric sensors [21,22]. Using the SIS sensor analyzed the interaction between E. amylovora and the LptE-functionalized S Figure 6 shows the dose-response curve plotted against the concentrations of e by a logarithmic scale, which displays a linearity (R 2 > 0.992) for wide dynami tween 10 0 and 10 7 cells/mL.…”
Section: Single-cell Detection Of E Amylovoramentioning
confidence: 99%
See 1 more Smart Citation
“…Specifically, the SIS sensor operates by directing in through a buffer solution, a bio-layer, and a substrate layer (SiO2). In this con the buffer solution serves as the incident medium, whose role is to provide temperature and humidity environment; errors due to refractive index chan tremely eliminated at the Brewster angle, resulting in a sensitivity more tha higher than conventional ellipsometric sensors [21,22]. Using the SIS sensor analyzed the interaction between E. amylovora and the LptE-functionalized S Figure 6 shows the dose-response curve plotted against the concentrations of e by a logarithmic scale, which displays a linearity (R 2 > 0.992) for wide dynami tween 10 0 and 10 7 cells/mL.…”
Section: Single-cell Detection Of E Amylovoramentioning
confidence: 99%
“…A comparison of various diagnostic methods for E. amylovora detection is described in Table 1. A promising sensor platform based on silicon, called SIS sensor, has been developed that can replace the traditional gold film used in Surface Plasmon Resonance (SPR) sensors [20,21]. The traditional SPR sensors need an additional reference channel to eliminate the noise signal from refractive index changes of the buffer solution and the gold thin film induced by variations of surrounding environments such as temperature and flow conditions [22,23].…”
Section: Introductionmentioning
confidence: 99%
“…Early diagnosis of acute myocardial infarction (AMI), via high-sensitive detection of its specific biomarker, can effectively treat the disease and significantly reduce the mortality rate [1,2]. Troponin is a regulatory protein of the thin filament of striated muscle, released into the bloodstream 4 to 6 hours after AMI and the peak levels occur at 18 to 24 hours [3].…”
mentioning
confidence: 99%
“…Zhihe Guo and Xuyang Zhao have contributed equally to this work. prognostic information supporting risk stratification and highly accurate diagnostics at the early stage [2,9].…”
mentioning
confidence: 99%
See 1 more Smart Citation