Novel Active Personal Nanoparticle Sampler for the Exposure Assessment of Nanoparticles in Workplaces

Abstract: A novel active personal nanoparticle sampler (PENS), which enables the collection of both respirable particulate mass (RPM) and nanoparticles (NPs) simultaneously, was developed to meet the critical demand for personal sampling of engineered nanomaterials (ENMs) in workplaces. The PENS consists of a respirable cyclone and a micro-orifice impactor with the cutoff aerodynamic diameter (d(pa50)) of 4 μm and 100 nm, respectively. The micro-orifice impactor has a fixed micro-orifice plate (137 nozzles of 55 μm in t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

5
76
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 92 publications
(81 citation statements)
references
References 28 publications
5
76
0
Order By: Relevance
“…(Stk 50 ) 1/2 is seen to deviate from the theoretical value of Marple and Liu (1974), 0.477 and that of Radar and Marple (1985), 0.49. This finding is consistent with that found by Tsai et al (2012). In addition, the minimum S/W ratio of the 9th-10th stages corresponds to a higher (Stk 50 ) 1/2 than that of the 8th stage, because the pressure drop across the former is larger than the latter.…”
Section: Cutoff Characteristics Of Three Lower Stages Of the Nmcisupporting
confidence: 92%
See 4 more Smart Citations
“…(Stk 50 ) 1/2 is seen to deviate from the theoretical value of Marple and Liu (1974), 0.477 and that of Radar and Marple (1985), 0.49. This finding is consistent with that found by Tsai et al (2012). In addition, the minimum S/W ratio of the 9th-10th stages corresponds to a higher (Stk 50 ) 1/2 than that of the 8th stage, because the pressure drop across the former is larger than the latter.…”
Section: Cutoff Characteristics Of Three Lower Stages Of the Nmcisupporting
confidence: 92%
“…Equation (11) was further validated by the experimental data of the micro-orifice impactor with smooth nozzle shape in Tsai et al (2012) with the porosity of 0.9% and the Re of 385. The d pa50 value estimated by Equation (11) is 120 nm which is close to the design value of 100 nm.…”
Section: Cutoff Characteristics Of Three Lower Stages Of the Nmcimentioning