2007
DOI: 10.1093/rpd/ncm058
|View full text |Cite
|
Sign up to set email alerts
|

Novel Al2O3:C,Mg fluorescent nuclear track detectors for passive neutron dosimetry

Abstract: The latest advances in the development of a fluorescent nuclear track detector (FNTD) for neutron and heavy charged particle dosimetry are described and compared with CR-39 plastic nuclear etched track detectors (PNTDs). The technique combines a new luminescent aluminium oxide single crystal detector (Al 2 O 3 :C,Mg) with an imaging technique based on laser scanning and confocal fluorescence detection. Detection efficiency was obtained after irradiations with monoenergetic neutron and proton beams. Dose depend… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
9
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 33 publications
(11 citation statements)
references
References 5 publications
2
9
0
Order By: Relevance
“…The sensitivity of FNTD to thermal neutrons with 6 LiF (TLD-600) as a converter (Fig. 4b) is 6500 tracks mm −2 mSv −1 , which is also consistent with the sensitivity reported previously (Akselrod et al, 2006b andSykora et al, 2007a). The track density per 1 mSv of dose for the thermal component of FNTD obtained using TLD-600 is 300 times higher than the HDPE component, making the thermal component almost insensitive to fast neutrons.…”
Section: Dose Dependencesupporting
confidence: 89%
See 2 more Smart Citations
“…The sensitivity of FNTD to thermal neutrons with 6 LiF (TLD-600) as a converter (Fig. 4b) is 6500 tracks mm −2 mSv −1 , which is also consistent with the sensitivity reported previously (Akselrod et al, 2006b andSykora et al, 2007a). The track density per 1 mSv of dose for the thermal component of FNTD obtained using TLD-600 is 300 times higher than the HDPE component, making the thermal component almost insensitive to fast neutrons.…”
Section: Dose Dependencesupporting
confidence: 89%
“…The sensitivity S to fast neutrons obtained from the FNTD-HDPE detector configuration is 21.5 tracks mm −2 mSv −1 and is consistent with preliminary results (Akselrod et al, 2006b andSykora et al, 2007a). In comparison, the sensitivity of CR-39 to fast neutrons is 12.1 tracks mm −2 mSv −1 .…”
Section: Dose Dependencesupporting
confidence: 88%
See 1 more Smart Citation
“…FNTD response to neutrons in track counting mode has been investigated in detail in our recent works (Sykora et al, 2007 andSykora et al, 2008). The dose response was shown to be linear in the range from 0.1 mSv to 300 mSv (personal dose equivalent H p (10)).…”
Section: Neutron Responsementioning
confidence: 99%
“…There have been numerous recent developments in various fields, two such examples are: new fluorescent nuclear track detectors based on Al 2 O 3 :C, Mg single crystals were tested and calibrated in parallel with CR-39 plastic nuclear etched track detectors (PNTDs) in different neutron fields and with monoenergetic protons (Sykora et al, 2007). Good fast to thermal neutron discrimination was demonstrated.…”
Section: ) a Similar Conversion Can Be Induced In Ycomentioning
confidence: 99%