2023
DOI: 10.1016/j.foodchem.2022.134522
|View full text |Cite
|
Sign up to set email alerts
|

Novel application of 1H NMR spectroscopy coupled with chemometrics for the authentication of dark chocolate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 29 publications
0
7
0
Order By: Relevance
“…The Permutations Plot helps to evaluate the authenticity of the current PLS-DA model ( Figure 2 D). When all the green R 2 values to the left are lower than the R 2 value of the original point to the right, it further confirms the credibility of the original model [ 30 ]. The results of the modeling analysis were as follows: with a cumulative explanatory power parameter R 2 Y (cum) it was 0.971, with R 2 X (cum) it was 0.835, and with the predictive power parameter Q 2 (cum) it was 0.947.…”
Section: Resultsmentioning
confidence: 59%
“…The Permutations Plot helps to evaluate the authenticity of the current PLS-DA model ( Figure 2 D). When all the green R 2 values to the left are lower than the R 2 value of the original point to the right, it further confirms the credibility of the original model [ 30 ]. The results of the modeling analysis were as follows: with a cumulative explanatory power parameter R 2 Y (cum) it was 0.971, with R 2 X (cum) it was 0.835, and with the predictive power parameter Q 2 (cum) it was 0.947.…”
Section: Resultsmentioning
confidence: 59%
“…Moreso, spectral data were pretreated by means of baseline (Automatic Whittaker Filter, asymmetry = 0.001, lambda = 100) to reduce the spectral noise, followed by Pareto scaling and mean-centering. Pareto-scaling is the preferred treatment for NMR data for adjusting the magnitude of each variable without increasing the noise [ 17 ].…”
Section: Methodsmentioning
confidence: 99%
“…The cross-validation for all the statistical models was performed by using the Venetian-blind method with 10 data splits. The number of principal components (PCs) was selected according to the smallest root mean squared error in calibration (RMSEC) and cross-validation (RMSECV) [ 17 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Among the arsenal of instrumental techniques available, infrared spectroscopy (IR) and mass spectrometry (MS) are the preferred ones ( Figure 1 a). Other detection techniques, such as nuclear magnetic resonance (NMR), spectroscopies (UV and fluorescence), electroanalytical analyses, or electronic noses, were less exploited in this field [ 20 , 21 , 22 , 23 , 24 , 25 ].…”
Section: Fingerprinting-based Authenticationmentioning
confidence: 99%