1982
DOI: 10.1063/1.1137103
|View full text |Cite
|
Sign up to set email alerts
|

Novel directional ion energy analyzer

Abstract: A new ion energy analyzer with high angular resolution (⩽3×10−4 sr) is described. It consists of a microchannel plate followed by a retarding-grid type analyzer. The microchannel plate is not used for charge multiplication but as a geometric filter with narrow angular passband (ϑ≃0.6°) yet high transparency (T≃60%). The energy analyzer is used to measure the true velocity space distribution of low-energy ion beams (Eb = 10–100 eV) in a double plasma device. Its superior performance over the conventional gridde… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
0

Year Published

1984
1984
2007
2007

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 78 publications
(22 citation statements)
references
References 8 publications
0
22
0
Order By: Relevance
“…In a way, these results agree with those obtained for the micro-porous ion energy analyzers used in some double plasma devices. Also in these cases only those ions having a velocity vector exactly aligned with the pores of the analyzer reach the collector (Stenzel et al, 1982). We also note the large potential variations originating from the differences in charge density on the two sides of extrusions facing towards and away the plasma flow, respectively.…”
Section: Figmentioning
confidence: 89%
“…In a way, these results agree with those obtained for the micro-porous ion energy analyzers used in some double plasma devices. Also in these cases only those ions having a velocity vector exactly aligned with the pores of the analyzer reach the collector (Stenzel et al, 1982). We also note the large potential variations originating from the differences in charge density on the two sides of extrusions facing towards and away the plasma flow, respectively.…”
Section: Figmentioning
confidence: 89%
“…It results in an erroneous, broaden IEDF. Stenzel et al 22 proposed an energy analyzer with high angular resolution where the ions are filtered with a microchannel plate. A layout of such an energy analyzer, specially designed and implemented Fig.…”
Section: Experimental Performancementioning
confidence: 99%
“…The observed energy boost was 17 eV, more than double the energy with the helicon alone, as shown in Figures 8 and 9. Two-dimensional contour plots of the ion velocity phase space distribution functions that were obtained by rotating the RPA, shot-to-shot 58,59 , are shown in Figure 9. Evidence of pitch angle scattering by neutrals may be seen in both panels of Figure 9.…”
Section: Ion Cyclotron Resonance Heating (Icrh)mentioning
confidence: 99%
“…Nonetheless, the effect of significant particle heating is apparent. Full ion velocity phase space distribution functions can be obtained by rotating the RPA, shot-to-shot 58,59 . Two dimensional color contour plots of a planar cut through the distribution function are shown in Figure 13 for ICRHoff and Figure 14 for 14 kW of ICRH-on.…”
Section: B Deuterium 20 Kw Icrhmentioning
confidence: 99%