2019
DOI: 10.1016/j.enconman.2019.03.025
|View full text |Cite
|
Sign up to set email alerts
|

Novel experiments on COP improvement of thermoelectric air coolers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 49 publications
(12 citation statements)
references
References 28 publications
0
11
0
1
Order By: Relevance
“…T w,o and T w,i are the water temperatures at the outlet and inlet of the condenser ( • C). Using Equation (2) [32], the COP was calculated for open-loop and closed-loop systems. In an open-loop system, heated water from the condenser is dumped directly to the outside, while water at the heat storage tank circulates and is reheated at the condenser and returns to the heat storage tank for a closed-loop system:…”
Section: Cop Of the Awhpmentioning
confidence: 99%
“…T w,o and T w,i are the water temperatures at the outlet and inlet of the condenser ( • C). Using Equation (2) [32], the COP was calculated for open-loop and closed-loop systems. In an open-loop system, heated water from the condenser is dumped directly to the outside, while water at the heat storage tank circulates and is reheated at the condenser and returns to the heat storage tank for a closed-loop system:…”
Section: Cop Of the Awhpmentioning
confidence: 99%
“…Building technology has emerged as one region of particular interest for thermoelectric applications. Numerous works have examined the possibility to use thermoelectrics for the purpose of air conditioning in theoretical [13][14][15][16] and experimental [17][18][19][20][21][22][23] setups. The predominant use case is the cooling case, while one study focuses on an IoT-control approach and also uses the heating function in reversed operation mode [23].…”
Section: Introductionmentioning
confidence: 99%
“…Irshad implements 24 TEEs with heat sinks in an supply air duct and reaches cooling COPs of 0.679 at a cooling load of 500 W. The excess heat is transferred to outdoor air [22,23]. The effect of joining several TEEs in series in an air flow is investigated by [17]. They find that the efficiency of 6 joined TEE is twice the effiency of only 2 TEE when operating at the same total electrical power input.…”
Section: Introductionmentioning
confidence: 99%
“…Besides, the thermal design and optimization will generate positive significance for the thermoelectric refrigeration system performance improvement. [24][25][26][27] For example, Chen et al 28 explored the influence of external heat exchangers that favors improving the thermoelectric cooling performance. Riffat and Ma 29 introduced the heat exchanger thermal resistance for calculating the hot-end temperature by considering the natural convection, forced air convection, and water-cooled exchanger.…”
Section: Introductionmentioning
confidence: 99%