Novel fast ultra‐performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) and extraction of ethylglucuronide in meconium samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…In the method presented here, a small amount of sample was necessary, 300 mg, which is acceptable in comparison to previous publications using between 200 and 2000 mg [7][8][9][10][11][12][13][14][15][16][17][18]. Several extraction procedures have been applied to meconium toxicological analysis including liquid-liquid extraction [9], salting out assisted liquid-liquid extraction [14] and solid-phase extraction (SPE) [11][12][13][15][16][17][18]. SPE is widely employed to prepare and clean up complex matrices in the field of forensic analysis and is the most widely used method for the preparation of meconium.…”
Section: Methods Development and Validationmentioning
confidence: 68%
See 3 more Smart Citations
“…In the method presented here, a small amount of sample was necessary, 300 mg, which is acceptable in comparison to previous publications using between 200 and 2000 mg [7][8][9][10][11][12][13][14][15][16][17][18]. Several extraction procedures have been applied to meconium toxicological analysis including liquid-liquid extraction [9], salting out assisted liquid-liquid extraction [14] and solid-phase extraction (SPE) [11][12][13][15][16][17][18]. SPE is widely employed to prepare and clean up complex matrices in the field of forensic analysis and is the most widely used method for the preparation of meconium.…”
Section: Methods Development and Validationmentioning
confidence: 68%
“…The matrix is very pasty and sticky, requiring a complex analytical pre-treatment and the sample amount is sometimes limited, allowing a single analysis. In the method presented here, a small amount of sample was necessary, 300 mg, which is acceptable in comparison to previous publications using between 200 and 2000 mg [7][8][9][10][11][12][13][14][15][16][17][18]. Several extraction procedures have been applied to meconium toxicological analysis including liquid-liquid extraction [9], salting out assisted liquid-liquid extraction [14] and solid-phase extraction (SPE) [11][12][13][15][16][17][18].…”
Section: Methods Development and Validationmentioning
confidence: 97%
See 2 more Smart Citations
“…EtG was used as a biomarker for prenatal alcohol exposure. Meconium samples were analyzed using ultrahigh performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS), with detection and quantification limits of 0.5 ng/g and 5 ng/g, respectively [30]. The cutoff point to consider EtG positive was 30 ng/g [31].…”
Section: Meconium Toxicology Testing For Analysis Of Etgmentioning