2004
DOI: 10.1016/j.talanta.2003.10.034
|View full text |Cite
|
Sign up to set email alerts
|

Novel fused-LEDs devices as optical sensors for colorimetric analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
70
0
1

Year Published

2005
2005
2017
2017

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 78 publications
(73 citation statements)
references
References 15 publications
2
70
0
1
Order By: Relevance
“…3 using the amount of light I reaching the detector and the amount I 0 in the absence of indicator membrane [41]. The value t 0 corresponds to the discharge time obtained in the absence of the indicator membrane and t to the discharge time of the membrane at any CO2 concentration.…”
Section: Instrument Response To Carbon Dioxidementioning
confidence: 99%
See 1 more Smart Citation
“…3 using the amount of light I reaching the detector and the amount I 0 in the absence of indicator membrane [41]. The value t 0 corresponds to the discharge time obtained in the absence of the indicator membrane and t to the discharge time of the membrane at any CO2 concentration.…”
Section: Instrument Response To Carbon Dioxidementioning
confidence: 99%
“…In this technique the photocurrent generated by the emitter LED and later modified by the sample, discharges the detector LED at a rate which is related to the intensity of light that reaches the detector, which can be tracked by a simple microprocessor circuit. Therefore, instead of measuring the photocurrent directly, a simple timer circuit is used to measure the time taken for the photocurrent generated by the emitter LED to discharge the detector LED to give a digital output directly without using an A/D converter or operation amplifier [41][42][43].…”
mentioning
confidence: 99%
“…A common, 660-nm LEDs served as detector as the LED is sufficiently sensitive through the spectrum below the emission wavelength. (Lau et al 2004) 3. Results and Discussion…”
Section: Portable Centrifugal Microfluidic Analytical System (Cmas)mentioning
confidence: 99%
“…380-900nm), have a long lifetime, robust and easy to fabricate into various configurations. When used as light detectors for chemical sensing by measuring the intensity-dependent discharge of capacitance, they have been found to be highly sensitive and could detect sub micro molar of dye 3 .…”
Section: Introductionmentioning
confidence: 99%
“…Mims et al [16][17] first investigated using LED as a crude light detector to measure photocurrent generated by direct sunlight. Previously, we demonstrated the use of a Paired Emitter Detector Diode (PEDD) device for colour and pH measurements in static solution 3 .…”
Section: Introductionmentioning
confidence: 99%