2017
DOI: 10.1109/tie.2017.2682784
|View full text |Cite
|
Sign up to set email alerts
|

Novel Hybrid LLC Resonant and DAB Linear DC–DC Converter: Average Model and Experimental Verification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 58 publications
(35 citation statements)
references
References 29 publications
0
35
0
Order By: Relevance
“…To again ensure voltage of , 5 does reach zero, (33) is derived, which upon reorganized, gives (34). Equation 34is thus the boundary condition of the output full bridge, which upon fulfilled, guarantees ZVS of 5 when driven by SPS during discharging.…”
Section: -Applying Conventional Sps With No DC Voltage Component Ormentioning
confidence: 99%
See 2 more Smart Citations
“…To again ensure voltage of , 5 does reach zero, (33) is derived, which upon reorganized, gives (34). Equation 34is thus the boundary condition of the output full bridge, which upon fulfilled, guarantees ZVS of 5 when driven by SPS during discharging.…”
Section: -Applying Conventional Sps With No DC Voltage Component Ormentioning
confidence: 99%
“…According to (40), deadtime of the discharging output full bridge using the proposed modulation scheme can also be expressed as (44), which upon substituted with expressions for 4 in (39) and 4 in (41), yields (45). (41) (15), (25), (27), (34), and (43), maps in Fig. 8 can then be obtained for projecting soft-switching and hardswitching regions of the DAB when it discharges with different load and output dc voltage conditions.…”
Section: Voltage Acrossmentioning
confidence: 99%
See 1 more Smart Citation
“…However, this time domain analysis method requires knowing the details of all circuit topology and control strategies of the whole system and establishing the time-domain state space model. The modeling process is very complex [8][9][10]. In order to adapt to a complex cascade system structure, a frequency domain analysis method based on the impedance model can be used.…”
Section: Introductionmentioning
confidence: 99%
“…In order to get other something important, complex analytic variables need to be taken full use of. In [ 35 ] and [ 36 ], seventh-order state equations which contain real and imaginary parts are used. Average absolute primary current and output voltage are the output variables of converter.…”
Section: Introductionmentioning