2022
DOI: 10.3390/app122211682
|View full text |Cite
|
Sign up to set email alerts
|

Novel Infrared Approach for the Evaluation of Thermofluidic Interactions in a Metallic Flat-Plate Pulsating Heat Pipe

Abstract: A novel and advanced analysis tool, based on the resolution of the inverse heat conduction problem, is used to evaluate wall-to-fluid heat fluxes in a metallic flat-plate pulsating heat pipe. The device under analysis is made of copper and formed by 16 channels having a squared section of 3 × 3 mm2 and filled with a water–ethanol mixture (20 wt.% of ethanol) with a volumetric filling ratio of 50%. One flat side of the device is externally coated with a highly emissive paint to perform temperature measurements … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

3
30
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(33 citation statements)
references
References 48 publications
3
30
0
Order By: Relevance
“…Conclusions on the fluid oscillations and heat flux amplitudes were drawn. Lastly, a novel method, similarly based on the IHCP resolution approach, was proposed by Pagliarini et al [26] for wall-to-fluid heat flux estimation in an FPPHP made of copper. Statistical reductions were performed on the resulting wall-to-fluid heat flux amplitudes.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…Conclusions on the fluid oscillations and heat flux amplitudes were drawn. Lastly, a novel method, similarly based on the IHCP resolution approach, was proposed by Pagliarini et al [26] for wall-to-fluid heat flux estimation in an FPPHP made of copper. Statistical reductions were performed on the resulting wall-to-fluid heat flux amplitudes.…”
Section: Introductionmentioning
confidence: 99%
“…Statistical reductions were performed on the resulting wall-to-fluid heat flux amplitudes. In [27], the figures of merit referred to fluid oscillations and transverse conduction in the same FPPHP device, analyzed through the same experimental and post-processing approach in [26], were collected and presented. The outcomes resulting from each experimental campaign were capable of quantitatively outlining the inner thermo-fluid dynamics of the investigated systems, even without any presence of transparent inserts for direct fluid visualizations.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…PHPs are extremely easy and cost effective compared to other heat transport devices [20]. They cope with elevated heat power due to the phase change phenomena and to the substantial sensible heat transfer carried out by the continual pulsations [21,22]. Moreover, PHPs are totally passive, so they avoid electric energy consumption and allow a compact power supply unit, and their adoption in the battery pack could also represent a promising approach to attain a uniform temperature.…”
Section: Introductionmentioning
confidence: 99%