2020
DOI: 10.1007/s12127-020-00265-0
|View full text |Cite
|
Sign up to set email alerts
|

Novel ion drift tube for high-performance ion mobility spectrometers based on a composite material

Abstract: Ion mobility spectrometers (IMS) are able to detect pptV-level concentrations of substances in gasses and in liquids within seconds. Due to the continuous increase in analytical performance and reduction of the instrument size, IMS are established nowadays in a variety of analytical field applications. In order to reduce the manufacturing effort and further enhance their widespread use, we have developed a simple manufacturing process for drift tubes based on a composite material. This composite material consi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 13 publications
(12 citation statements)
references
References 25 publications
0
12
0
Order By: Relevance
“…Drift tube ion mobility spectrometry (DTIMS) is potentially the simplest of the ion mobility techniques based on a simplified structural and parameter interplay [2,4]. The drift tube is filled with a defined volume of buffer gas with no directional flow, which acts as a velocity regulator to moving ions [4].…”
Section: Types Of Ion Mobility 31 Dtimsmentioning
confidence: 99%
See 3 more Smart Citations
“…Drift tube ion mobility spectrometry (DTIMS) is potentially the simplest of the ion mobility techniques based on a simplified structural and parameter interplay [2,4]. The drift tube is filled with a defined volume of buffer gas with no directional flow, which acts as a velocity regulator to moving ions [4].…”
Section: Types Of Ion Mobility 31 Dtimsmentioning
confidence: 99%
“…Drift tube ion mobility spectrometry (DTIMS) is potentially the simplest of the ion mobility techniques based on a simplified structural and parameter interplay [2,4]. The drift tube is filled with a defined volume of buffer gas with no directional flow, which acts as a velocity regulator to moving ions [4]. The ions are propelled through the drift tube by a uniformly applied, static electric field with a decreasing voltage as the ions traverse the drift tube [2,4].…”
Section: Types Of Ion Mobility 31 Dtimsmentioning
confidence: 99%
See 2 more Smart Citations
“…Consequently, system miniaturization is necessary. Different approaches for miniaturized IMS drift tubes have been presented, still showing fast response times and low detection limits [13][14][15][16][17]. However, gas mixtures always pose a challenge for IMS not only due to the limited resolving power but moreover due to chemical cross sensitivities associated with atmospheric pressure chemical ionization (APCI).…”
Section: Introductionmentioning
confidence: 99%