2015
DOI: 10.1016/j.talanta.2015.01.045
|View full text |Cite
|
Sign up to set email alerts
|

Novel potentiometric application for the determination of pantoprazole sodium and itopride hydrochloride in their pure and combined dosage form

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 44 publications
(26 citation statements)
references
References 29 publications
0
26
0
Order By: Relevance
“…However, PVC must be used with a plasticizer or solvent mediator for two reasons: the first one is to prevent membrane cracking by giving it much elasticity. The second one is the solubilization of the ion exchanger and thereby modifying its distribution constant .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, PVC must be used with a plasticizer or solvent mediator for two reasons: the first one is to prevent membrane cracking by giving it much elasticity. The second one is the solubilization of the ion exchanger and thereby modifying its distribution constant .…”
Section: Resultsmentioning
confidence: 99%
“…Nowadays electrochemical techniques specially, ion selective electrodes (ISEs), has made great progress and achievement in the field of pharmaceutical analysis. This can be owed to its simplicity, rapidity, portability, lower energy consumption and its applicability to colored and turbid solutions . Searching the literature, no attempt was found for the selective determination of LD in presence of its toxic metabolite DMA by ISE.…”
Section: Introductionmentioning
confidence: 99%
“…26,27 RESEARCH ARTICLE The results in Table 2 also demonstrate that the anodized EPPG has a better response characteristics compared with the other carbon-based electrodes (CP 23 and GC 24,25 ). Compared with the chemically modified electrodes, [28][29][30][31][32] the EPPG electrode exhibited a higher analytical performance especially in terms of detection limit and sensitivity (Table 2). These results indicate that by carefully selecting the best electrode among different available carbon-based structures, it is possible to develop a simple analytical method based on direct electro-oxidation of analyte molecules on the electrode surface and to achieve analytical performance comparable or even better than the methods based on time-consuming and complicated electrode surface modification procedures by metals, 28 metal oxides, 32 or polymers.…”
Section: Comparison Of the Developed Methods With Other Electrochemicamentioning
confidence: 99%
“…These results indicate that by carefully selecting the best electrode among different available carbon-based structures, it is possible to develop a simple analytical method based on direct electro-oxidation of analyte molecules on the electrode surface and to achieve analytical performance comparable or even better than the methods based on time-consuming and complicated electrode surface modification procedures by metals, 28 metal oxides, 32 or polymers. [29][30][31] …”
Section: Comparison Of the Developed Methods With Other Electrochemicamentioning
confidence: 99%
See 1 more Smart Citation