2023
DOI: 10.3390/ma16072871
|View full text |Cite
|
Sign up to set email alerts
|

Novel Reinforcing Techniques and Bearing Capacity Analysis for Tunnel Lining Structures with Extensive Corrosion

Abstract: Affected by the erosive environment, tunnel lining concrete in the long-term service zprocess often exhibits engineering diseases such as concrete corrosion degradation and loss of strength, decreasing the stability of the tunnel lining structure and the traffic safety. Based on HTG tunnel project, the basic distribution rule of tunnel lining corrosion and macro mechanical properties of corroded concrete were explored in this paper through engineering disease site investigation. Then, on this basis, aiming at … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 20 publications
0
1
0
Order By: Relevance
“…It was shown that the augmentation effect diminishes beyond an ECC thickness of 70 mm. The available scholarly literature [27] pertaining to the beam bending test of a concrete-ECC combination indicates that the increase provided by ECC becomes less significant when the thickness of the ECC exceeds 0.2 H. Based on the findings presented in this study, it is seen that the calculation outcomes exhibit greater levels of satisfaction when η = h ECC /h=0.35. Upon further examination, it is evident that the thorough evaluation of ECC thickness and hoop rate demonstrates superior outcomes when using a thickness of 70 mm as opposed to 100 mm.…”
Section: The Effect Of Concrete Strength On Shear-bearing Capacitymentioning
confidence: 61%
“…It was shown that the augmentation effect diminishes beyond an ECC thickness of 70 mm. The available scholarly literature [27] pertaining to the beam bending test of a concrete-ECC combination indicates that the increase provided by ECC becomes less significant when the thickness of the ECC exceeds 0.2 H. Based on the findings presented in this study, it is seen that the calculation outcomes exhibit greater levels of satisfaction when η = h ECC /h=0.35. Upon further examination, it is evident that the thorough evaluation of ECC thickness and hoop rate demonstrates superior outcomes when using a thickness of 70 mm as opposed to 100 mm.…”
Section: The Effect Of Concrete Strength On Shear-bearing Capacitymentioning
confidence: 61%