1988
DOI: 10.1007/bf02398294
|View full text |Cite
|
Sign up to set email alerts
|

Nuclear orientation at isolde/cern

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

1992
1992
2010
2010

Publication Types

Select...
8
2

Relationship

3
7

Authors

Journals

citations
Cited by 30 publications
(12 citation statements)
references
References 7 publications
0
12
0
Order By: Relevance
“…The reaction products diffused out of the 1900 • C hot target and effused via a hot transfer line to a FEBIAD-type "hot plasma" ion source. The atoms were ionized to 1 + ions, extracted, accelerated to 60 keV, mass separated by the ISOLDE General Purpose Separator (GPS) [10,11], and finally transported through the beam distribution system to be implanted into an iron foil inside the NICOLE 3 He- 4 He dilution refrigerator [8,12]. The 69 As + beam intensity after mass separation was typically about 2 × 10 6 ions/s at an average proton beam intensity of 2.5 µA.…”
Section: Experiments and Formalismmentioning
confidence: 99%
“…The reaction products diffused out of the 1900 • C hot target and effused via a hot transfer line to a FEBIAD-type "hot plasma" ion source. The atoms were ionized to 1 + ions, extracted, accelerated to 60 keV, mass separated by the ISOLDE General Purpose Separator (GPS) [10,11], and finally transported through the beam distribution system to be implanted into an iron foil inside the NICOLE 3 He- 4 He dilution refrigerator [8,12]. The 69 As + beam intensity after mass separation was typically about 2 × 10 6 ions/s at an average proton beam intensity of 2.5 µA.…”
Section: Experiments and Formalismmentioning
confidence: 99%
“…After diffusing out of the target, the 221 Fr nuclei were ionized in a W surface ion source [27], accelerated to 60 keV, and mass selected by the General Purpose Separator [28]. The radioactive ions were subsequently transported to the NICOLE LTNO setup [24,29], where they were implanted into the cooled Au or Si sample. A SRIM calculation [30] showed that the implantation depth of 221 Fr ions with an energy of 60 keV is 80Å for Au and 330Å for Si.…”
Section: The Experimentsmentioning
confidence: 99%
“…These isotopes were produced directly and one after the other implanted on line ͑at 60 keV͒ into the same iron foil ͑purity 99.998%, thickness 50 m͒ that was soldered to the cold finger of the NICOLE 3 He- 4 He dilution refrigerator. 10 The 221 Fr source was prepared by implanting 221 Rn (T 1/2 ϭ25 min) produced on a ThC 2 target. After implantation the 221 Rn ␤ Ϫ decayed to 221 Fr.…”
Section: Experiments and Resultsmentioning
confidence: 99%