Encyclopedia of Inorganic Chemistry 2005
DOI: 10.1002/0470862106.ia321
|View full text |Cite
|
Sign up to set email alerts
|

Nuclear Resonance Vibrational Spectroscopy ( NRVS )

Abstract: Nuclear Resonance Vibrational Spectroscopy (NRVS) utilizes the simultaneous excitation of the Mössbauer nucleus and vibrational quanta. Vibrational features appear as sidebands on the recoilless resonance. NRVS reveals the complete vibrational spectrum of the probe nucleus with the resolution almost equal to that of Raman or infrared. Major advantages include selectivity to vibrations of the Mössbauer isotope with quantitative information on vibrational amplitudes, as well as frequencies. Single crystal measur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 78 publications
0
4
0
Order By: Relevance
“…3. The quantitative nature of NRVS is underscored by the fact that the area of each peak is equal to a quantity named mode composition factor ejα2, 17,31 defined as the fraction of the total kinetic energy of mode α associated with motion of atom j . The individual peaks and the corresponding eitalicSn2 values are listed in Table 1.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…3. The quantitative nature of NRVS is underscored by the fact that the area of each peak is equal to a quantity named mode composition factor ejα2, 17,31 defined as the fraction of the total kinetic energy of mode α associated with motion of atom j . The individual peaks and the corresponding eitalicSn2 values are listed in Table 1.…”
Section: Resultsmentioning
confidence: 99%
“…Their rich spectra are fairly well understood (particularly above 400 cm –1 ), with band assignments having been reported for numerous metalloporphyrins with various metal centers, peripheral groups, and axial ligands, as well as for metal-free compounds. Much newer is the synchrotron-based nuclear resonance vibrational spectroscopy (NRVS) technique, , also known as nuclear inelastic scattering (NIS) or nuclear resonant inelastic X-ray scattering (NRIXS), available only at a few third-generation synchrotron facilities. NRVS takes advantage of tunable, highly brilliant, stable X-ray beams to target a specific (Mössbauer) isotope, regardless of the complexity of the molecule investigated.…”
Section: Introductionmentioning
confidence: 99%
“…[93][94][95][96][97][98][99][100][101][102][103][104][105] This provides the opportunity to study the ligation and oxidation state of a specific site. The high brilliance of SR allows us to measure the PDOS even for small samples, i.e., measurements under extreme conditions in which the accessible sample space is severely limited are possible.…”
Section: Detectormentioning
confidence: 99%
“…For example, NRVS has been used to assign metal-ligand vibrational modes of diatomic molecules coordinated to porphyrins 26,28,29 and to detect nitrosylated iron-sulfur clusters in proteins. 30,31 NRVS and density functional theoretical (DFT) studies of mononuclear Fe(III)–OOH 32 and Fe(IV)=O 33,34 compounds have provided insight into their distintive chemical properties.…”
mentioning