2023
DOI: 10.1016/j.nds.2023.06.001
|View full text |Cite
|
Sign up to set email alerts
|

Nuclear Structure and Decay Data for A=44 Isobars

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 622 publications
0
2
0
Order By: Relevance
“…On a radiotracer scale, applications of titanium have been investigated using two radiotitanium isotopes: titanium-44 ( 44 Ti) and titanium-45 ( 45 Ti). Titanium-44 is a radioisotope with a very long half-life of 60 years and potential applications as part of a 44 Ti/ 44 Sc generator system [14][15][16]. The decay of 44 Ti to 44 Sc (t 1/2 = 3.97 h, mean E β+ = 0.632 MeV (branching ratio (BR) 94.27%)), and the secular equilibrium due to the half-life difference makes this a potential source for a constant supply of 44 Sc at research sites [16][17][18].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…On a radiotracer scale, applications of titanium have been investigated using two radiotitanium isotopes: titanium-44 ( 44 Ti) and titanium-45 ( 45 Ti). Titanium-44 is a radioisotope with a very long half-life of 60 years and potential applications as part of a 44 Ti/ 44 Sc generator system [14][15][16]. The decay of 44 Ti to 44 Sc (t 1/2 = 3.97 h, mean E β+ = 0.632 MeV (branching ratio (BR) 94.27%)), and the secular equilibrium due to the half-life difference makes this a potential source for a constant supply of 44 Sc at research sites [16][17][18].…”
Section: Introductionmentioning
confidence: 99%
“…Titanium-44 is a radioisotope with a very long half-life of 60 years and potential applications as part of a 44 Ti/ 44 Sc generator system [14][15][16]. The decay of 44 Ti to 44 Sc (t 1/2 = 3.97 h, mean E β+ = 0.632 MeV (branching ratio (BR) 94.27%)), and the secular equilibrium due to the half-life difference makes this a potential source for a constant supply of 44 Sc at research sites [16][17][18]. Titanium-45 is of interest for positron emission tomography (PET) applications due to the characteristic properties of this radionuclide including its half-life of 3.08 h, its decay by positron emission (BR 85%), its low mean positron energy (E β + 439 keV) and very small fractions of other gamma rays (720 keV (0.15%)) [19,20].…”
Section: Introductionmentioning
confidence: 99%