1999
DOI: 10.1107/s0909049599000758
|View full text |Cite
|
Sign up to set email alerts
|

Numerical determination of a true absorption spectrum from grazing-incidence fluorescence EXAFS data

Abstract: The fluorescence EXAFS spectra, measured at a grazing incidence angle larger than the critical angle for total reflection, were examined to test a numerical conversion from the distorted fluorescence data to the 'true' absorption spectra, achieving a reliable transferability between the transmission and the fluorescence data. Under various entrance and exit angles, full numerical corrections were made in terms of the sample's selfabsorption, the measurement geometry, and the energy dependent efficiency functio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
4
0

Year Published

2000
2000
2012
2012

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…The Au Lα fluorescence was detected by a 19-element Ge solid-state detector (GL0110S, Canberra, USA) at room temperature. Self-absorption was negligible because the coverage was sufficiently small, i.e., 1.5 × 10 13 atoms/cm 2 …”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The Au Lα fluorescence was detected by a 19-element Ge solid-state detector (GL0110S, Canberra, USA) at room temperature. Self-absorption was negligible because the coverage was sufficiently small, i.e., 1.5 × 10 13 atoms/cm 2 …”
Section: Methodsmentioning
confidence: 99%
“…Self-absorption was negligible because the coverage was sufficiently small, i.e., 1.5 × 10 13 atoms/cm 2 . 26 EXAFS analysis was carried out by REX 2000 (Rigaku Co., Japan). 11,27 The EXAFS oscillations were extracted using a spline smoothing method with a Cook−Sayers criterion 28 and normalized by an edge height with its energy dependence expressed in a Victoreen equation.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Polarization-dependent XAFS is measured at the coverage of 4 × 10 14 and 1 × 10 14 atoms/cm 2 . The self-absorption effect is negligible in our case because the coverage was sufficiently small . We use the notation of (111) fcc , (100) fcc and so on to show the direction of Ni fcc plane to distinguish the notation of the TiO 2 (110) surface.…”
Section: Methodsmentioning
confidence: 99%