In the present study, two various passive methods for heat transfer enhancement, including conical ring and wire coil are placed in a tube as turbulators. Four conical rings with four side holes are utilized with the same distance. The wire coil is employed at the center of the tube. The considered Reynolds numbers are between 4000 and 10,000. The studied geometrical parameters contain the pitch and diameter of a wire coil. Four different pitches of wire coil, including 10, 12, 14, and 16 mm, are evaluated. Furthermore, four values of wire coil diameter such as 2, 4, 6, and 8 mm are certain. The obtained numerical results displayed that by declining the pitch of a wire coil (37.5%), the average Nusselt number increases by about 143%. Also, augmentation in wire coil diameter by 300% leads to a growth in average Nusselt number by about 131%. Moreover, owing to utilizing two various turbulators, the pressure drop is significantly high in comparison with the bare tube. At Re = 10,000, growth in the inner diameter of the wire coil by 300% leads to an increase in thermal performance by about 36.12%. Moreover, as the pitch of the wire coil rises by 60%, the thermal performance declines by about 35.71%.