2021
DOI: 10.1002/er.7357
|View full text |Cite
|
Sign up to set email alerts
|

Numerical investigation of a vertical triplex‐tube latent heat storage/exchanger to achieve flexible operation of nuclear power plants

Abstract: The current numerical investigation is carried out to assess the possibility of integrating a latent heat thermal energy storage (TES) in a nuclear power plant (NPP) system. This would allow improving the capability of such plants to operate in a load-following mode by eliminating the gap between energy supply and energy demand by the grid. In contrary to previously published TES designs, the phase change material (PCM) triplex-tube containers are vertically oriented in the present study to take advantage of m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 43 publications
0
6
0
Order By: Relevance
“…It is interesting to note that the HTF temperature at the outlet of a control volume (i) is considered equal to the input temperature of the control volume (i + 1). The used convective heat transfer coefficient (h f ) is determined using the following equation [15,29]:…”
Section: Properties Valuementioning
confidence: 99%
See 1 more Smart Citation
“…It is interesting to note that the HTF temperature at the outlet of a control volume (i) is considered equal to the input temperature of the control volume (i + 1). The used convective heat transfer coefficient (h f ) is determined using the following equation [15,29]:…”
Section: Properties Valuementioning
confidence: 99%
“…The use of phase change materials (PCMs) as a storage medium is advantageous for concentrated solar power technologies [13]. Mohamed Ali et al [14,15] have shown the potential of using the PCM tanks to reduce energy consumption and to overcome the problem of a mismatch between energy supply and energy demand. Recently, a solar cooling system using sensible thermal storage and evacuated tube collectors was proposed by Yadav et al [16].…”
Section: Introductionmentioning
confidence: 99%
“…Unfortunately, it is quite common for such devices to ignite, which leads to fires. In addition, when resonant phenomena occur, protective devices can be triggered, thereby reducing the reliability of the power supply (Bondarenko and Galich 2013;Ali et al 2022). Figure 16 presents graphs showing the connection of a capacitor device without throttles to a device.…”
Section: The Effect Of Reactive Power Compensation Devices On Harmoni...mentioning
confidence: 99%
“…The present paper focusses on LTES heat exchangers. LTES heat exchangers are developed in various geometries such as packed beds [9][10][11], corrugated plate heat exchangers [12], triplex tube heat exchangers [13], tube in tube heat exchangers [14] and perhaps most commonly shell and tube heat exchangers [15]. For all of these geometries, the design of the system first involves selecting a PCM material with an appropriate phase change temperature.…”
Section: Introductionmentioning