Numerical investigation of the resistance of precast RC pinned beam‐to‐column connections under shear loading

Abstract: Summary In precast technology, the effective design and construction are related to the behaviour of the connections between the structural members in order to cater for all service, environmental and earthquake load conditions. Therefore, the design and detailing of the connections should be undertaken consistently and with awareness of the desired structural response. In the research presented herein, an analytical expression is proposed for the prediction of the resistance of precast pinned connections unde… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
15
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(17 citation statements)
references
References 10 publications
2
15
0
Order By: Relevance
“…It can be seen that 25 mm thick of U-shaped HDR pad exhibits a 3% to 5% higher maximum strength than specimens of other HDR thickness. The phenomenon of thicker U-shaped HDR rubber in the hook-end beam-column joint has decreasing strength is similar to the parametric study by Kremmyda et al [14]. However, the numerical results do not tally with Kremmyda et al [14] when thinner U-shaped HDR pads were used.…”
Section: Numerical Resultssupporting
confidence: 77%
See 1 more Smart Citation
“…It can be seen that 25 mm thick of U-shaped HDR pad exhibits a 3% to 5% higher maximum strength than specimens of other HDR thickness. The phenomenon of thicker U-shaped HDR rubber in the hook-end beam-column joint has decreasing strength is similar to the parametric study by Kremmyda et al [14]. However, the numerical results do not tally with Kremmyda et al [14] when thinner U-shaped HDR pads were used.…”
Section: Numerical Resultssupporting
confidence: 77%
“…The phenomenon of thicker U-shaped HDR rubber in the hook-end beam-column joint has decreasing strength is similar to the parametric study by Kremmyda et al [14]. However, the numerical results do not tally with Kremmyda et al [14] when thinner U-shaped HDR pads were used. This is probably due to the hook-end connection not utilizing any dowel bar at the precast beam-column joint to achieve the shear strength.…”
Section: Numerical Resultssupporting
confidence: 77%
“…Interestingly, such protective effects persist even in case of delayed treatment (Oki et al, 2008). Arundic acid also decreased extracellular glutamate levels, leading to a decrease in infarct size in a rat model of cerebral ischemia (Pettigrew et al, 2006).…”
Section: Introductionmentioning
confidence: 94%
“…The connections between the principal beams and the columns are made by steel dowels protruding from the column, inserted into holes in the beams and subsequently grouted. The connections are designed with a shear action resulting from capacity design and a shear strength resulting from the following formulation [39], [40], [41].…”
Section: Beam-to-column Dowel Connectionmentioning
confidence: 99%