2017 Progress in Applied Electrical Engineering (PAEE) 2017
DOI: 10.1109/paee.2017.8009005
|View full text |Cite
|
Sign up to set email alerts
|

Numerical model of the 10 kVA superconducting transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…The computer model of the single-phase HTS 21 MVA 70/10.5 kV transformer was developed on the basis of a verified computer model of the HTS 10 kVA 230/115 V transformer with its physical counterpart in the Laboratory of Superconducting Technologies in Lublin, Electrotechnical Institute in Warsaw [6]. The waveforms obtained from the measurement of the no-load condition, the load condition, and the short-circuit condition as well as the transient waveforms described in [13,17] were subjected to verification. A comparison of the results obtained from the computer model with experimental waveforms for HTS transformer of the power 10 kVA with the SCS4050 tape windings is shown in Figure 1 for the inrush current and in Figure 2 for the short-circuit current.…”
Section: Pspice Model Of Hts Transformermentioning
confidence: 99%
See 4 more Smart Citations
“…The computer model of the single-phase HTS 21 MVA 70/10.5 kV transformer was developed on the basis of a verified computer model of the HTS 10 kVA 230/115 V transformer with its physical counterpart in the Laboratory of Superconducting Technologies in Lublin, Electrotechnical Institute in Warsaw [6]. The waveforms obtained from the measurement of the no-load condition, the load condition, and the short-circuit condition as well as the transient waveforms described in [13,17] were subjected to verification. A comparison of the results obtained from the computer model with experimental waveforms for HTS transformer of the power 10 kVA with the SCS4050 tape windings is shown in Figure 1 for the inrush current and in Figure 2 for the short-circuit current.…”
Section: Pspice Model Of Hts Transformermentioning
confidence: 99%
“…Energies 2022, x, x FOR PEER REVIEW 3 of 17 condition as well as the transient waveforms described in [13,17] were subjected to verification. A comparison of the results obtained from the computer model with experimental waveforms for HTS transformer of the power 10 kVA with the SCS4050 tape windings is shown in Figure 1 for the inrush current and in Figure 2 To develop a computer model of a single-phase transformer HTS 21 MVA 70/10.5 kV, a computational design was used, taking into account the geometric, electrical, and thermal parameters of the transformer and its windings.…”
Section: Pspice Model Of Hts Transformermentioning
confidence: 99%
See 3 more Smart Citations