2021
DOI: 10.1088/1755-1315/781/4/042008
|View full text |Cite
|
Sign up to set email alerts
|

Numerical Simulation Study on Hydraulic Transients in Hydropower Station with Trigeminy Surge Tank

Abstract: A static and dynamic model for hydraulic transient calculation of three-throttled-orifice surge tank was established based on the basic equations of surge tank, by using structure matrix method (matrix analysis of structure?). Control conditions in an engineering practice were calculated by a simplified model and a three-throttled-orifice model respectively. The results indicate that the maximum pressure at the volute end, the maximum rising rate of unit speed and the water level extremum of the surge tank are… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…In summary, the influence of the time constant of pressure inertia on the critical stable section area of the surge tank is analyzed according to the established fifth-order mathematical model of the critical stable section area of the surge tank combined with a typical large hydropower station system [8][9][10][11] . The results show that when the value of Te (time constant of the flow inertia in the pressure pipe) decreases from 1.8 to 0.2, the critical stable section area of the surge tank only decreases by 3.33 m 2 , which is equivalent to 0.78%.…”
Section: Discussionmentioning
confidence: 99%
“…In summary, the influence of the time constant of pressure inertia on the critical stable section area of the surge tank is analyzed according to the established fifth-order mathematical model of the critical stable section area of the surge tank combined with a typical large hydropower station system [8][9][10][11] . The results show that when the value of Te (time constant of the flow inertia in the pressure pipe) decreases from 1.8 to 0.2, the critical stable section area of the surge tank only decreases by 3.33 m 2 , which is equivalent to 0.78%.…”
Section: Discussionmentioning
confidence: 99%
“…In the aspect of foreign research, Yao et al established a wear prediction model for the guide vane of hydraulic turbine [5], and carried out related research. JIANG Jia-Rui et al conducted a numerical simulation study on the internal flow field of long blades and short blades of high-head mixed-flow turbine [6] [7]. In addition, Hongyu G et al conducted numerical simulation and experimental research on the hydraulic performance of centrifugal pumps as turbines [8] [9].…”
Section: Research Status At Home and Abroadmentioning
confidence: 99%