The sonic nozzle is commonly used in flow measurement. However, the non-equilibrium condensation phenomenon of moist air in the nozzle has a negative effect on the measuring accuracy.To investigate this complex phenomenon, the experiments on the oscillating condensation flow of moist air were conducted by an adjustable humidification apparatus with different relative humidity (0-100%), temperature (30-50°C) and carrier gas pressure (1-6 bar), where the micro size pressure measuring system was designed by Bergh-Tijdeman (B-T) Model. The accurate mathematical model of nonequilibrium condensation was also built and validated by the experimental data of time-averaged pressure distribution. Then, the frequency and intensity of pressure fluctuation of oscillating flow at a wide range of operation condition were obtained combining experimental data and physical simulation model. Importantly, a new semi-empirical relation of dimensionless frequency deduced from dimensionless analysis was identified accurately by experimental data. Finally, the signal nonstationarity was also observed by using the continuous wavelet transform (CWT). The instantaneous frequency saltation and the energy attenuation of pressure signals were observed in the condensation flow.