2015
DOI: 10.1016/j.applthermaleng.2015.04.014
|View full text |Cite
|
Sign up to set email alerts
|

Numerical study of horizontal ground heat exchanger for high energy demand applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 62 publications
(21 citation statements)
references
References 11 publications
0
21
0
Order By: Relevance
“…Following the approach of [43] In heating mode, the thermal load of BHE (Q BHE ) is lower than that of the building and it can be expressed as: COP QQ Normally, the COP of a specific heat pump is not constant and is often represented as function of the heat pump inlet fluid temperature. In this work the relationship between the outlet fluid temperature of BHE and COP is assumed to be as defined by [45]:…”
Section: Boundary Conditionsmentioning
confidence: 99%
“…Following the approach of [43] In heating mode, the thermal load of BHE (Q BHE ) is lower than that of the building and it can be expressed as: COP QQ Normally, the COP of a specific heat pump is not constant and is often represented as function of the heat pump inlet fluid temperature. In this work the relationship between the outlet fluid temperature of BHE and COP is assumed to be as defined by [45]:…”
Section: Boundary Conditionsmentioning
confidence: 99%
“…Therefore, the refrigeration cycle are selected as a typical analysis. When operate for heating, the thermal load of heat pump is expressed in Eq (1) [11] .…”
Section: Methodsmentioning
confidence: 99%
“…Although the required site area for this system is small, the system has a high initial cost for drilling and installation of the GHE. Meanwhile, the horizontal (shallow) closed-loop system is relatively inexpensive, as it requires no vertical borehole and just shallow trenches that can be dug through manual (human) labor or mechanical means, such as the use of a mini-excavator [16][17][18]. However, this system requires a larger footprint for installation.…”
Section: Introductionmentioning
confidence: 99%
“…The horizontal closed system is increasingly being studied. Several studies have compared shallow linear, helical, and slinky GHEs in numerical simulation, and have found that the helical configuration has the best performance [16,17,19]. They have also found that the thermal conductivity surrounding a GHE and the flowrate of the heat transfer fluids are the most important parameters.…”
Section: Introductionmentioning
confidence: 99%