Based on the perspective of flight technology and flight safety, the unsaturated clayey foundation soil of a high plateau airport in the mountainous area of southwest China is taken as the research object, and the calculation method of the composite modulus of CFG pile composite foundation with the soil between the piles as the unsaturated soil is established according to the relevant characteristics of unsaturated soil, and the calculation method of the composite foundation's settlement is carried out on the basis of this method. At the same time, Plaxis finite element analysis software is used to model the actual project and numerically analyze the settlement characteristics of the composite foundation. Finally, the calculation results of the two methods are compared and studied with the actual settlement monitoring values on site. The study shows that: 1) the theoretical analysis method is able to consider the effects of pile length, pile modulus, and matrix suction in unsaturated soil of rigid piles on the composite modulus, which is more in line with the reality than the conventional composite modulus method that does not consider the unsaturated nature of the soil between the piles; 2) the resultant values computed by the theoretical and numerical analysis methods recommended in this paper are both smaller than those measured at the site but the difference is within the range of 10%, so that in the actual plateau of the High Plains airports can choose the two analysis methods recommended in this paper to conduct related research.